AC Pass
On delivery, ports are provided with insulating fuses. Desired AC pass is obtained
by turning the fuse holder
after connecting
the cable or before disconnecting, to
prevent damage of cable connectors.
Caution:
Permanent excess of maximum remote current may cause damage.
Low Voltage Lockout
For all coax line powered power supplies an undervoltage switch type 75018-xx can
be delivered that switches off the power supply if the voltage drops below the rated
value (24 V or 35 V) thus, the network is not damaged due to increased current
consumption.
Setting up the amplifier
The handheld terminal type 91200 is used to set up the amplifier. Use the menu
structure in the following table to navigate through the different menus.
Shortcuts
Use the short cuts shown on the cover plate to do a fast selection of the required
menu.
For example: The output equalizer is marked with
5
. By pressing the button ”5” for
approximately 1 sec. the terminal jumps to the menu where the output equalizer can
be is changed.
The menu numbers can also be used as short cuts. Refer to the following menus
structure (Fig. 3) to determine the number for the required menu.
For example: Press ”35” and the handheld terminal will jump to the menu where the
reverse switch can be set.