2-31
Cisco 7201 Installation and Configuration Guide
OL-11364-04
Chapter 2 Installing the Cisco 7201 Router
Connecting Power
Figure 2-29
Inserting Wires into the Terminal Block Plug
Step 7
Insert the exposed wire of one of the four DC-input power source wires into the terminal block plug, as
shown in
Figure 2-29
. Make sure that you cannot see any wire lead. Only wire with insulation should
extend from the terminal block.
Figure 2-30
Torquing the Terminal Block Plug Captive Screws
Caution
Do not overtorque the terminal block plug captive screws. The recommended maximum torque is from
0.5 Nm (4.425 lbf in.) to 0.6 Nm (5.310 lbf in.).
1
Negative (–)
3
Negative (–)
2
Return (+)
4
Return (+)
170975
A
B
1
2
3
4
1
Torque is from 0.5 Nm (4.425 lbf in. to 0.6 Nm (5.310 lbf in.)
170974
1