Maximum
Minimum
Environmental Characteristic
40 degree C
(40 degrees C at 10,000
feet)
0 degree C
Steady State Operating
+70 degrees C
-20 degrees C
Storage
90%
10%
Humidity operating (noncondensing)
95%
5%
Humidity nonoperating (noncondensing)
10,000 feet
-500 feet
Altitude operating: over allowable temperature range
(0 to 40 degrees C)
50,000 feet
-1000 feet
Altitude, nonoperating: over allowable temperature
range
+70 degrees C
-25 degrees C
Thermal shock non-operating with change over time
of 3 minute
+40 degrees C
0 degrees C
Thermal Shock - Operating at 2.5 degree C per minute
Mounting Requirements
The height, width, depth and weight of the chassis are displayed in this table:
Measurement
Characteristic
1.73 inches (4.39 cm) — 1RU rack-mount
Height
12.70 inches (32.258 cm)
Width
10.0 inches (25.4 cm)
Depth
6.6 lbs. (2.99 kg)
Weight
To place the system in a proper location, it is necessary to know the dimensions of the device's chassis.
The Cisco 5100 ENCS can be placed on a desktop or installed in a rack. The mounting ears for the device are
designed for #12-24 UNC screws.
The location of your device and the layout of your equipment rack or wiring room are extremely important
considerations for proper operation. Equipment placed too close together, inadequate ventilation, and
inaccessible panels can cause malfunctions and shutdowns, and can make maintenance difficult. Plan for
access to both front and rear panels of the device.
This information can help you plan the rack configuration for your equipment:
• Allow clearance around the rack for maintenance.
• Allow at least one rack unit of vertical space between devices.
Preparing for Installation
4
Preparing for Installation
Mounting Requirements