2-56
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
PLATFORM_RPC Messages
PLATFORM_RPC Messages
This section contains platform-specific remote procedure call (RPC) messages. The RPC function in the
switch stack allows instances of code running on the various systems in a stack to intercommunicate by using
a virtual function-call mechanism.
Error Message
PLATFORM_RPC-0-RESOURCE_CRASH: [chars].
Note
This message applies only to the Catalyst Switch Module 3110.
Explanation
The system is unable to allocate memory for RPC. [chars] describes the error message.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
“Error Message Traceback Reports” section on page 1-6
Error Message
PLATFORM_RPC-3-BAD_CLASS: Bad Class in RPC message: [int].
Note
This message applies only to the Catalyst Switch Module 3110.
Explanation
There is a missing entry in the class table for a message class. [int] is the number of the
missing message class.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
“Error Message Traceback Reports” section on page 1-6
Error Message
PLATFORM_RPC-3-MSG_THROTTLED: RPC Msg Dropped by throttle mechanism:
type [int], class [int], max_msg [int], total throttled [int].
Note
This message applies only to the Catalyst Switch Module 3110.
Explanation
There are too many outgoing messages queued for a message class. An RSP message
was dropped. The first [int] is the message type, the second [int] is the message class, the third [int]
is the maximum number of messages that can be queued before throttling occurs, and the last [int]
is the total number of messages that have been throttled.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the