2-51
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
PLATFORM _IPC Messages
Error Message
PLATFORM_HPLM-6-LABEL_COMPLETE: VRF Label compaction complete.
Explanation
The VRF label compaction process has successfully completed.
Recommended Action
No action is required.
Error Message
PLATFORM_HPLM-6-LABEL_FAILED: VRF Label compaction failed.
Explanation
The VRF label compaction process has failed.
Recommended Action
No action is required.
Error Message
PLATFORM_HPLM-6-LABEL_START: VRF Label compaction started.
Explanation
The VRF label compaction process has started.
Recommended Action
No action is required.
PLATFORM _IPC Messages
This section contains the Inter-Process Communication (IPC) protocol messages. The IPC protocol
handles communication between the stack master switch and stack member switches.
Error Message
PLATFORM_IPC-3-COMMON: [chars].
Note
This message applies only to the Catalyst Switch Module 3110.
Explanation
There has been an IPC failure. [chars] describes the error message.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
“Error Message Traceback Reports” section on page 1-6
Error Message
PLATFORM_IPC-3-MASTER: [chars].
Note
This message applies only to the Catalyst Switch Module 3110.
Explanation
There has been an IPC failure on the stack master. [chars] describes the error message.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the