24-2
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 24 Configuring CDP
Configuring CDP
For a switch and connected endpoint devices running Cisco Medianet
•
CDP identifies connected endpoints that communicate directly with the switch.
•
To prevent duplicate reports of neighboring devices, only one wired switch reports the location
information.
•
The wired switch and the endpoints both send and receive location information.
For information, go to:
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_cdp_discover.html.
The switch supports CDP Version 2.
CDP and Switch Stacks
A switch stack appears as a single switch in the network. Therefore, CDP discovers the switch stack, not
the individual stack members. The switch stack sends CDP messages to neighboring network devices
when there are changes to the switch stack membership, such as stack members being added or removed.
Configuring CDP
These sections contain this configuration information:
•
Default CDP Configuration, page 24-2
•
Configuring the CDP Characteristics, page 24-3
•
Disabling and Enabling CDP, page 24-3
•
Disabling and Enabling CDP on an Interface, page 24-4
Default CDP Configuration
shows the default CDP configuration.
Table 24-1
Default CDP Configuration
Feature
Default Setting
CDP global state
Enabled
CDP interface state
Enabled
CDP timer (packet update frequency)
60 seconds
CDP holdtime (before discarding)
180 seconds
CDP Version-2 advertisements
Enabled
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...