8-2
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 8 Configuring SDM Templates
Understanding the SDM Templates
The rows in the tables represent approximate hardware boundaries set when a template is selected. If a
section of a hardware resource is full, all processing overflow is sent to the CPU, seriously impacting
switch performance.
SDM Templates and Switch Stacks
All stack members use the same SDM template that is stored on the stack master. When a new switch is
added to a stack, as with the switch configuration and VLAN database files, the SDM configuration that
is stored on the stack master overrides the template configured on an individual switch. For more
information about stacking, see
Chapter 6, “Managing Switch Stacks.”
You can use the
show switch
privileged EXEC command to see if any stack members are in SDM
mismatch mode. This example shows the output from the
show switch
privileged EXEC command when
an SDM mismatch exists:
Switch#
show switch
Current
Switch# Role Mac Address Priority State
------------------------------------------------------------
*2 Master 000a.fdfd.0100 5 Ready
4 Member 0003.fd63.9c00 5 SDM Mismatch
This is an example of a syslog message notifying the stack master that a stack member is in SDM
mismatch mode:
2d23h:%STACKMGR-6-SWITCH_ADDED_SDM:Switch 2 has been ADDED to the stack (SDM_MISMATCH)
2d23h:%SDM-6-MISMATCH_ADVISE:
2d23h:%SDM-6-MISMATCH_ADVISE:
2d23h:%SDM-6-MISMATCH_ADVISE:System (#2) is incompatible with the SDM
2d23h:%SDM-6-MISMATCH_ADVISE:template currently running on the stack and
2d23h:%SDM-6-MISMATCH_ADVISE:will not function unless the stack is
2d23h:%SDM-6-MISMATCH_ADVISE:downgraded. Issuing the following commands
Table 8-1
Approximate Number of Feature Resources Allowed by Each Template
Resource
Default QoS
Dual
LAN base
routing
Unicast MAC addresses
8 K
8 K
8 K
4 K
IPv4 IGMP groups
256
256
256
256
IPv4 unicast routes
0
0
0
4.25 K
•
Directly connected hosts
0
0
0
4 K
•
Indirect routes
0
0
0
256
IPv6 multicast groups
0
0
0
0
Directly connected IPv6 addresses
0
0
0
0
Indirect IPv6 unicast routes
0
0
0
0
IPv4 policy-based routing aces
0
0
0
0
IPv4 MAC QoS ACEs
128
384
0
128
IPv4 MAC security ACEs
384
128
256
384
IPv6 security aces
0
0
0
0
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...