![CISA 59751 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/cisa/59751/59751_installers-instructions_2608779005.webp)
5
1
Push the rod
5
until it touches the front bracket
3.
3
Pull the front bracket lever
3
outwards to check it is fully open.
2
Place the rear bracket
4
against the end of the rod
5
.
4
Connect the power supply cable
14
.
T.4
PANIC EXIT DEVICE INSTALLATION
4
14
CSA 4,2x19
3,2 mm
D
CSA 4,2x19
T.5
WIRING
MOTOR CHARACTERISTICS
Power supply voltage
12
Absorbed current (max)
1.5A @ 12V
Degree of protection
IP X0
Operating temperature
-10 ÷ +55°C
Certifications See “Regulatory Addendum”
1
Hold open switch (optional)
2
Remote opening button
3
Ext V 1 = 12V , min I = 1 mA
4
Lock closed LED (optional) ext V 2 = 12V , max I = 0.5 A
5
Int V = 12V , I = 2 A
6
Lock open LED (optional) ext V 3 = 12V , max I = 0.5 A
7
Programming cable Item 1.07030.41.0 (optional)
8
This configuration is an alternative to 5
Power supply with battery charger (UPS function)
Class B 12V , I=2A. Buffer battery 12V, 0.8Ah
Recommended when installing device on fire doors
WARNING:
Do not connect the product directly to the mains 230V ~.
CISA declines all responsibility for the compliance of the existing
system to current regulations.
1
3
5
7
N.C.
11
N.C.
2
4
6
8
N.C.
12
N.C.
2
1
14
13
8,5 mm
16 mm
Pinout
Colour
fo
Signal
Descriptions
Specifications
1
Green
TX -
Programming cable
-
2
Green/White
TX +
3
Orange
OUT1 / C
Lock status securely locked
12 V , max I = 0.5 A
4
Orange/White
OUT1 / NO
5
Brown
OUT2 / C
Lock status open
12 V , max I = 0.5 A
6
Brown/White
OUT2 / NO
7
Blue
IN1+
Input for opening
12 V , 12V ~
Min I = 1mA
8
Blue/White
IN1-
9
-
-
Not connected
-
10
-
-
Not connected
-
11
Red
V+
Power supply
12 V , I = 1.5 A
12
Black
V-
13
-
-
Not connected
-
14
-
-
Not connected
-
T
XD
+
T
XD -
GN
D
V
est 3
V
est 2
V
est 1
1
2
3
4
6
7
7
7
+
-
8
5
PSU
+
-
PSU
+
-
Batt
Opzionale