VCC-F22U29APCL
Rev.900-675-31-00
©2009 CIS Corporation. All rights reserved.
10
Manual Gain Control
008
0
~
255:
-1dB
~
+12dB
※
Set the data of address 001 to 004.
Manual Shutter Control
009&
010
0
~
1251:
1/20s
~
1/40000s
※
Set the data of address 002 to 016.
Address 009 MSB and address 010 LSB makes 10bit in total.
Shutter Speed
=
(1251.6-Data) x 39.11
μ
s
Max Data =
4E3h =
1251
Trigger Polarity
011
0:
Positive Input
1: Negative
Input
No Function
012
0:
Fixed. Do not change.
Output Data Selection 013
0:
*Set the data of Address 003 to 000
~
004.
RAW 8 bit output data 8 bit output data
1:
RAW 10 bit output data
2:
PoCL-Lite RAW 8 bit output data
3:
PoCL-Lite 10 RAW bit output data
Trigger Reset Mode
014
0:
H-Synchronous Mode
1:
CLK-Synchronous Mode
Data Save
015
Input 083 to save address 000
~
014 into EEP-ROM.
Note: Please note the followings when using trigger shutter mode.
Re-triggering at H-Synchronous Mode shall be after 2H of CCD read out signal.
Re-triggering at CLK-Synchronous Mode shall be after completion of video output.