Function 

Address  Data   

Gamma Mode 

014 

0:  Gamma OFF(1.0) 
1:  Gamma On 

(Option) 

Partial Scan Mode 

015 

0:  Full Frame Scan Mode 

 

1:  Partial Scan Mode 

Partial Scan Start Position 

016&017  0

685:   

Set the data of address 015 to 001. 

Address 016 MSB and address 017 LSB makes total 16bit. 
Start Position:3 H/step    Min Data:0(0 H) / Max Data:685(2055 H) 
Start Position (016&017) + Effective Line (019&020) should be <= 685. 

Partial Scan Effective Line 

019&020  0

684:   

Set the data of address 015 to 001. 

Address 019 MSB and address 020 LSB makes total 16bit. 
Effective Line:3 H/step    Min Data:0(3 H) / Max Data:685(2058 H) 
Start Position (016&017) + Effective Line(019&020) should be <= 685. 

Partial Scan Total Line 

021&022  0

2078:  Read Only 

Total line number at Partial Scan Mode or Full Frame Scan Mode minus 1 
is to be set 

Baud Rate 

030 

0:  9600bps 
1:  19200bps 
2:  38400bps 
3:  57600bps 
4:  115200bps 

Frame ID ON/OFF 

060 

0:  OFF 
1:  ON 

Software Trigger 

061 

0:  Software Trigger On 
Light access is recognized as a trigger.    There is no need to prepare a 
pulse trigger with data values. 

 

SOPT Mode 

062 

0:  45M

 

Mode 

1:  125M

 

Mode 

SOPT Standby 

063 

0:  Standby OFF 
1:  External Trigger Standby 
2:  Software Trigger Standby 

SOPT Long Term Exposure 
Mode 

098&099  2079: 

OFF: Operates at fixed trigger shutter setting. 

2080

64449: 

ON: 
Exposure Time=(098&099) x 32.07

μ

s + 27.73

μ

Internal Trigger Cycle=

((098&099) + 321) x 32.07

μ

s + 27.73

μ

s

 

Manual Digital Gain   
(Right) 

126&127  256

512:   

256:×1(0dB)

512:×2(+6dB) 

Set the data of address 001 to 004. 

Manual Digital Gain    (Left) 

128&129  256

512:   

256:×1(0dB)

512:×2(+6dB) 

Set the data of address 001 to 004. 

Data Save 

255 

Input 083 or 053 to save the data in EEP-ROM. 

 

※ 

In this Specification, we describe pixel shifting technology as “SOPT: Spatial Offsetting Pickup

 

Technique”. 

  The data set with 2 Byte shall be set with High Byte first, then set with Low Byte.    The camera rewrites 

the internal resister when receiving Low Byte. 

Содержание VISION:elite VCC-GM60FV11CL

Страница 1: ...VCC GM60FV11CL Rev 900 713 32 2012 CIS Corporation All rights reserved 125M Ultra High Resolution B W Camera Link VCC GM60FV11CL Product Specification Operational Manual CIS Corporation English...

Страница 2: ...Connector 12226 1100 00 PL SUMITOMO 3M 12 7 Timing Chart 13 7 1 Horizontal Synchronous Signals Timing 13 7 2 Full Frame Scan Mode 13 7 3 Fixed Trigger Shutter Mode 14 7 4 Pulse Width Trigger Shutter...

Страница 3: ...on systems to try and evaluate it Do not use or store the camera in the following extreme conditions Extremely dusty or humid places Extremely hot or cold places operating temperature 5 to 40 Close to...

Страница 4: ...ing when rising 2ch output CCD separated into right and left is utilized for VCC G60FV11CL Image signals for right half screen and left half screen are output via each independent circuit Therefore di...

Страница 5: ...1 43fps 700ms SOPT ON 125M Mode 125M Pixels approx 0 516fps 1 94s When SOPT is ON partial scan mode and pulse width trigger mode can not be used CLK Sync V Sync reset Trigger At SPOT OFF triggers can...

Страница 6: ...is OFF Approx 1 43fps Pixel numbers of the synthetic image Horizontal 7344 pixel Vertical 6174 pixel TTL pixels Approx 45 Mega pixels SOPT 125M Mode Frame rate of the synthetic image When long term ex...

Страница 7: ...terference and 2 this device must accept any interference received including interference that may cause undesired operation 19 Durability Vibration Acceleration 19 61m s2 2 0G Frequency 20 200 Hz Fre...

Страница 8: ...ger Input Polarity Positive Negative Selectable Pulse Width Over 2H min Under 4158H max Hardware Trigger Input LVTTL 5 0V Tolerant HR10 10R 12PA Software Trigger Input Serial Communications 4 Video Si...

Страница 9: ...ion All rights reserved 9 4 3 CCD Spectral Response Representative Value Lens charcteristics and luminous source charcteristics are not considered 4 4 Video Output Format 2 Taps Output Area of interes...

Страница 10: ...Shutter Refer to Address 009 and 010 Trigger Shutter Mode 004 0 Normal Shutter Mode Trigger Mode Off 1 Fixed Trigger Shutter Mode Shutter speed can be set with address 002 2 Pulse Width Trigger Shutt...

Страница 11: ...30 0 9600bps 1 19200bps 2 38400bps 3 57600bps 4 115200bps Frame ID ON OFF 060 0 OFF 1 ON Software Trigger 061 0 Software Trigger On Light access is recognized as a trigger There is no need to prepare...

Страница 12: ...a Link Connector 12226 1100 00 PL SUMITOMO 3M Pin No 1 GND 2 POWER IN DC 12V 3 GND 4 NA 5 GND 6 LVAL OUT 7 FVAL OUT 8 GND 9 Exposure Out 10 DVAL OUT 11 Trigger IN 12 GND Pin No Pin No 1 GND 14 GND 2 X...

Страница 13: ...utput 1 2 3 4 5 6 7 8 9 10 2076 2075 11 12 21 23 24 CCD Read Out Signal 9 H 21 H 2058 H 12 H Total 2079H 2079 2078 2077 2058 H 22 LVAL Output 700 CLK Video Output DVAL Output 700 CLK FVAL Output 1924...

Страница 14: ...trigger edge in the camera to starting exposure is 21 40 s Triggers can be accepted even when outputting video signals However shutter timing to start the next video output prior to the completion of...

Страница 15: ...the camera to starting exposure is 21 40 s The delay time from detecting trigger edge to complete exposure is 29 13 s Triggers can be accepted even when outputting video signals However shutter timing...

Страница 16: ...H 3 H step Effective line register Address 019 020 0 3 H 685 2058 H 3 H step Total line resister Address 021 022 706 H Effective line register 2 2 Read Only Note Reading out position and effective li...

Страница 17: ...Section 5 Function Settings 000 255 0 Dh W Write mode C Camera mode Camera No is fixed with 6 bytes numerical strings 000000 Process code Input any one of R W or C to the process code R read mode is...

Страница 18: ...n set with Low Byte The camera rewrites the internal resister when receiving Low Byte 10 Initial Settings Function Address Data Gain 001 0 0 dB E Shutter 002 0 1 15s OFF Trigger Shutter Mode 004 0 Nor...

Страница 19: ...125M Mode 45M 125M Send Control Command 000000W062000 Send Control Command 000000W062001 Software Trigger Mode Standby Send Control Command 000000W063002 Capturing Images Image synthesis Repeat Compl...

Страница 20: ...Change to 125M Mode 45M 125M Send Control Command 000000W062000 Send Control Command 000000W062001 External Trigger Mode Standby Send Control Command 000000W063001 Capturing Images Image Synthesis Re...

Страница 21: ...312H Fixed Delay 10ms SOPT Mode Setting Address 062 Data 000 45M mode SOPT Standby Setting Address 063 Data 002 Software Trigger SOPT Standby Address 063 Data 000 Standby off With receiving software...

Страница 22: ...4 2 4 3 4 4 4 0 0 1 0 2 0 3 0 4 0 0 3 1 3 2 3 3 3 4 3 0 1 1 1 2 1 3 1 4 1 0 2 1 2 2 2 3 2 4 2 0 4 1 4 2 4 3 4 4 4 0 0 1 0 2 0 3 0 4 0 0 3 1 3 2 3 3 3 4 3 0 1 1 1 2 1 3 1 4 1 0 2 1 2 2 2 3 2 4 2 0 4 1...

Страница 23: ...mages However when Frame ID is ON 0 Y and 2447 Y data are used as Frame ID Frame ID Data 8bit SOPT OFF Image 00 Hex SOPT ON Image 01 Hex 19 Hex 45M Mode 01 Hex 7D Hex 125M Mode Address 060 Data 0 Fram...

Страница 24: ...Datum Plane A 910 018 00 00 Dimensions from datum plane A to the center of the lens mount The center of the effective pixels shall be within 0 6 phai to the center of the lens mount Inclination of the...

Страница 25: ...VCC GM60FV11CL Rev 900 713 32 2012 CIS Corporation All rights reserved 25 14 Dimensions...

Страница 26: ...this product specification operation manual In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified In case damage or lo...

Отзывы: