VCC-GM60FV11CL
Rev. 900-713-32
©2012 CIS Corporation. All rights reserved.
11
Function
Address Data
Gamma Mode
014
0: Gamma OFF(1.0)
1: Gamma On
(Option)
Partial Scan Mode
015
0: Full Frame Scan Mode
1: Partial Scan Mode
Partial Scan Start Position
016&017 0
~
685:
※
Set the data of address 015 to 001.
Address 016 MSB and address 017 LSB makes total 16bit.
Start Position:3 H/step Min Data:0(0 H) / Max Data:685(2055 H)
Start Position (016&017) + Effective Line (019&020) should be <= 685.
Partial Scan Effective Line
019&020 0
~
684:
※
Set the data of address 015 to 001.
Address 019 MSB and address 020 LSB makes total 16bit.
Effective Line:3 H/step Min Data:0(3 H) / Max Data:685(2058 H)
Start Position (016&017) + Effective Line(019&020) should be <= 685.
Partial Scan Total Line
021&022 0
~
2078: Read Only
Total line number at Partial Scan Mode or Full Frame Scan Mode minus 1
is to be set
Baud Rate
030
0: 9600bps
1: 19200bps
2: 38400bps
3: 57600bps
4: 115200bps
Frame ID ON/OFF
060
0: OFF
1: ON
Software Trigger
061
0: Software Trigger On
Light access is recognized as a trigger. There is no need to prepare a
pulse trigger with data values.
SOPT Mode
062
0: 45M
Mode
1: 125M
Mode
SOPT Standby
063
0: Standby OFF
1: External Trigger Standby
2: Software Trigger Standby
SOPT Long Term Exposure
Mode
098&099 2079:
OFF: Operates at fixed trigger shutter setting.
2080
~
64449:
ON:
Exposure Time=(098&099) x 32.07
μ
s + 27.73
μ
s
Internal Trigger Cycle=
((098&099) + 321) x 32.07
μ
s + 27.73
μ
s
Manual Digital Gain
(Right)
126&127 256
~
512:
256:×1(0dB)
~
512:×2(+6dB)
※
Set the data of address 001 to 004.
Manual Digital Gain (Left)
128&129 256
~
512:
256:×1(0dB)
~
512:×2(+6dB)
※
Set the data of address 001 to 004.
Data Save
255
Input 083 or 053 to save the data in EEP-ROM.
※
In this Specification, we describe pixel shifting technology as “SOPT: Spatial Offsetting Pickup
Technique”.
※
The data set with 2 Byte shall be set with High Byte first, then set with Low Byte. The camera rewrites
the internal resister when receiving Low Byte.