VCC-FC41SX29CL
Rev.900-696-32-00
©2011 CIS Corporation. All rights reserved.
17
7.5.
60fps Trigger Shutter Mode Timing
□
Rolling Shutter system is adopted to VCC-FC41SX29CL so that electrical charge cannot be swept
out at one time to reset. Due to this rolling shutter system, images out-of-exposure signal
period will be superimposed. To avoid the superimposed images, please keep shooting
conditions dark or give sufficient stroboscopic lighting source when shooting.
□
Trigger operation is CLK sync, V-Sync Reset.
Delay time, from detecting the trigger edge to starting exposure, is as follows.
60fps Trigger Shutter Mode
: 0.15
μ
s
60fps Pulse Width Trigger Shutter Mode
□
Shutter Time (at Progressive Scan)
60fps Fixed Trigger Shutter Mode
: 1/120,000s (1H)
~
1/60s (2310H)
:
1H
Step
Resister
Assigned
(Address
009
&
010)
60fps Pulse Width Trigger Shutter Mode : 1/120,000s (8.222
μ
s)
~
1/60s (16.677ms)
: Pulse Width 7.222
μ
s x n + 1
μ
s (0
≦
n
≦
2309)
□
The shortest input interval (Tact Time) is as follows.
60fps Trigger Shutter Mode
: Shutter Time + Video Output Time
60fps Pulse Width Trigger Shutter Mode (Progressive: 16.683ms)
□
Trigger signals input prior to the completion of video output signals for the prior trigger shall be
ignored.