VCC-G20U20A
Rev.900-618-35-00
©2014 CIS Corporation. All rights reserved.
5
4. Specification
4.1. General Specification
Item
Specification
Pickup device
Device Type
1/1.8” Interline Transfer B/W CCD, Sony ICX274AL
Effective Pixel Number 1628(H) x 1236 (V)
Unit Cell Size
4.4μm (H) x 4.4μm (V)
Chip Size
8.5mm (H) x 6.8mm (V)
Video output frequency
Pixel Clock
36 MHz
Horizontal Frequency 18.75 kHz Pixel Clock: 1920 CLK
Vertical Frequency
Full Frame Scan Mode: 14.98 Hz, 1252H
Binning Mode: 29.95 Hz, 626H
1/2 Partial Scan Mode: 29.95 Hz, 626H
1/4 Partial Scan Mode: 59.91 Hz, 313H
Sync. system
Internal sync & HD/VD external sync
(Internal/External recognized automatically)
Video output standard Analog
Resolution
1200 TV lines
Sensitivity
F8 400 lx (Shutter 1/15s, Gain 0dB, 3200K)
Minimum illumination F1.4 1.0 lx (Shutter 1/15s, max Gain VS 50IRE)
S/N ratio
52dB
Dust or stains in
optical system
No dust or stain shall be detected on the testing screen with setting the camera
aperture at F16.
Power requirements
DC +12V ± 10% (Max voltage not to exceed 15V)
Power consumption
1.9 W (Max. 2.5W) at DC +12V IN
Dimension
Refer to overall dimension drawing (Clause 9)
29mm x 29mm x 29mm (excluding projection)
Weight
Approx. 45 g
Lens mount
C mount (Refer to overall dimension drawing)
Optical axis accuracy Refer to drawing for CCD Optical Axis Accuracy
(Clause 8)
Gain variable range
0
~
12dB (guaranteed range)
Gamma
1 (fixed)
Shutter speed
variable range
Fixed Switch: OFF (1/15), 1/120, 1/300, 1/600, 1/1,250, 1/2,500, 1/5,000,
1/10,000s
Pulse Width: 10
μ
s
~
250ms
Trigger shutter mode
・
Fixed trigger shutter mode
・
Pulse width trigger shutter mode