VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
18
This function is to output the test pattern from the camera. Please execute it to check system operation.
8.9
Indicator LED Lighting Control
DeviceControl
DeviceIndicatorMode
Active
ErrorStatus
Inactive
・
Active : To indicate the communication condition of CoaXPress.
・
ErrorStatus : Normally, the light is OFF. However, the light will turn on when system error occurs.
・
Inactive : To turn off all LEDs.
Please refer to the chart below for the lighting pattern at Active settings.
Lighting
Camera condition
Light OFF
PoCXP No supply
Green low-speed blinking [0.5 Hz]
Completion of device and host
connection
Green light ON
Video data transmitting
Orange low-speed blinking [1 Hz]
Trigger input waiting
Red high-speed blinking
System error
※
The camera might work fine even the red light is blinking. Also, the camera will remain indicating error once the camera has
recognized error, such as when put the trigger in restricted timing, or switch ROI or sub-sampling function while grabbing
image. Please execute power restoration or Device Control --- SensorReset to revert camera to normal lighting condition.
Indicator LED
Aegis Electronic Group, Inc.