![Cirrus SR22T Скачать руководство пользователя страница 458](http://html1.mh-extra.com/html/cirrus/sr22t/sr22t_pilot-operating-handbook_2608512458.webp)
16 of 52
P/N 13772-151
Section 9
Cirrus Design
Supplements
SR22T
Fluid Quantity Imbalance Caution
PFD Alerts Window: “Fluid quantity imbalance has been detected”
Imbalance between left and right sensed fluid quantity is greater than
1.0 gallon.
1. Revert to AUTO control of the fluid source to control the fluid
quantity.
If ANTI ICE FLO or ANTI ICE PSI annunciates:
a. Revert to manual control of the fluid source to control the fluid
level quantity
(1) Fluid Quantity ......................SWITCH TO FULLEST TANK
b. WIND SHLD Push-Button.............................................PRESS
(1) Repeat operation of windshield pump to verify metering
pumps are primed properly as evidenced by deicing fluid
exiting windshield nozzles.
If Caution Annunciation extinguishes:
a. Anti-Ice System ....................................................... MONITOR
If Caution Annunciation does not extinguish or intermittent:
a. Fluid Quantity ......................... SWITCH TO OPPOSITE TANK
b. WIND SHLD Push-Button.............................................PRESS
(1) Repeat operation of windshield pump to verify metering
pumps are primed properly as evidenced by deicing fluid
exiting windshield nozzles.
c. Icing Conditions .................................................. AVOID / EXIT
ANTI ICE QTY
Original Issue: 02-01-13
Содержание SR22T
Страница 14: ...1 2 P N 13772 005 Section 1 Cirrus Design General SR22T Original Issue Intentionally Left Blank...
Страница 56: ...2 30 P N 13772 005 Section 2 Cirrus Design Limitations SR22T Original Issue Intentionally Left Blank...
Страница 102: ...3 46 P N 13772 005 Section 3 Cirrus Design Emergency Procedures SR22T Original Issue Intentionally Left Blank...
Страница 128: ...4 2 P N 13772 005 Section 4 Cirrus Design Normal Procedures SR22T Original Issue Intentionally Left Blank...
Страница 158: ...4 32 P N 13772 005 Section 4 Cirrus Design Normal Procedures SR22T Original Issue Intentionally Left Blank...
Страница 160: ...5 2 P N 13772 005 Section 5 Cirrus Design Performance Data SR22T Original Issue Intentionally Left Blank...
Страница 194: ...6 2 P N 13772 005 Section 6 Cirrus Design Weight and Balance Data SR22T Original Issue Intentionally Left Blank...
Страница 206: ...6 14 P N 13772 005 Section 6 Cirrus Design Weight and Balance Data SR22T Original Issue Intentionally Left Blank...
Страница 210: ...7 4 P N 13772 005 Section 7 Cirrus Design Systems Description SR22T Original Issue Intentionally Left Blank...
Страница 302: ...8 2 P N 13772 005 Section 8 Cirrus Design Handling and Servicing SR22T Original Issue Intentionally Left Blank...
Страница 334: ...8 34 P N 13772 005 Section 8 Cirrus Design Handling and Servicing SR22T Original Issue Intentionally Left Blank...
Страница 366: ...8 of 8 P N 13772 131 Section 9 Cirrus Design Supplements SR22 SR22T Revision 02 01 06 10 Intentionally Left Blank...
Страница 402: ...6 of 6 P N 13772 136 Section 9 Cirrus Design Supplements SR22 SR22T Revision 01 01 06 10 Intentionally Left Blank...
Страница 412: ...4 of 4 P N 13772 146 Section 9 Cirrus Design Supplements SR22T Original Issue 11 16 2010 Intentionally Left Blank...
Страница 494: ...52 of 52 P N 13772 151 Section 9 Cirrus Design Supplements SR22T Original Issue 02 01 13 Intentionally Left Blank...
Страница 496: ...10 2 P N 13772 005 Section 10 Cirrus Design Safety Information SR22T Original Issue Intentionally Left Blank...