![Cirrus Logic CS8952 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/cirrus-logic/cs8952/cs8952_manual_2608619028.webp)
CS8952
28
CrystalLAN™ 100BASE-X and 10BASE-T Transceiver
onto RXD[3:0] synchronously with respect to
RX_CLK.
Receive errors are indicated during frame reception
by the assertion of RX_ER. It indicates that an error
was detected somewhere in the frame currently be-
ing transferred across the MII. RX_ER will transi-
tion synchronously with respect to the RX_CLK,
and will be held high for one cycle for each error re-
ceived. It is up to the MAC to ensure that a CRC er-
ror is detected in that frame by the Logical Link
Control. Figure 2 illustrates reception without er-
rors, and Figure 3 illustrates reception with errors.
4.3
MII Transmit Data
TX_EN is used by the MAC to signal to the
CS8952 that valid nibbles of data are being present-
ed across the MII via TXD[3:0]. TX_EN must be
asserted synchronously with the first nibble of pre-
amble, and must remain asserted as long as valid
data is being presented to the MII.
TX_EN must be de-asserted within one TX_CLK
cycle after the last nibble of data (CRC) has been
presented to the CS8952. When TX_EN is not as-
serted, data on TXD[3:0] is ignored.
Transmit errors should be signaled by the MAC by
asserting TX_ER for one or more TX_CLK cycles.
TX_ER must be synchronous with TX_CLK. This
will cause the CS8952 to replace the nibble with a
HALT symbol in the frame being transmitted. This
invalid data will be detected by the receiving PHY
and flagged as a bad frame. Figure 4 illustrates
transmission without errors, and Figure 5 illustrates
transmission with errors.
4.4
MII Management Interface
The CS8952 provides an enhanced IEEE 802.3 MII
Management Interface. The interface consists of
three signals: a bi-directional serial data line
(MDIO), a data clock (MDC), and an optional in-
terrupt signal (MII_IRQ). The Management Inter-
face can be used to access status and control
registers internal to the CS8952. The CS8952 im-
plements an extended set of 16-bit MII registers.
Eight of the registers are defined by the IEEE 802.3
RX_CLK
RX_DV
RXD[3:0]
RX_ER
Preamble/SFD
DATA
Figure 2. Reception without errors
RX_CLK
RX_DV
RXD[3:0]
RX_ER
Preamble/SFD
DATA
XX
DATA
Figure 3. Reception with errors