8. PROGRAMMING INFORMATION
www.cirrus.com
for evaluation prior to ordering a CDK. The
CDK2000 is designed with built-in features to ease the process of programming small quantities of devices for pro-
totype and small production builds. In addition to its field programming capabilities, the CDK2000 can also be used
for the complete evaluation of programmed CS2000-OTP devices.
The CS2000-OTP can also be factory programmed for large quantity orders. When ordering factory programmed
devices, the CDK should first be used to program and evaluate the desired configuration. When evaluation is com-
plete, the CS2000 Configuration Wizard is used to generate a file containing all device configuration information;
this file is conveyed to Cirrus Logic as a complete specification for the factory programming configuration. Please
contact your local Cirrus Logic sales representative for more information regarding factory programmed parts.
See the CDK2000 datasheet, available at
, for detailed information on the use of the CDK2000 pro-
gramming and evaluation tools.
Below is a form which represents the information required for programming a device (noted in gray). The
Descriptions” section beginning on page 22
describes the functions of each parameter. This form may be used ei-
ther for personal notation for device configuration or it can be filled out and given to a Cirrus representative in con-
junction with the programming file from the CDK2000 as an additional check. The User Defined Ratio may be filled
out in decimal or it may be entered as hex as outlined in
“Calculating the User Defined Ratio” on page 26
. For all
other parameters mark a ‘0’ or ‘1’ below the parameter name.
OTP Modal and Global Configuration Parameters Form
Modal Configuration Set #0
Ratio 0 (dec)
Ratio 0 (hex) __ __ : __ __ : __ __ : __ __
RModSel1
RModSel0
AuxOutSrc1 AuxOutSrc0
LockClk1
LockClk0
FracNSrc
Modal Configuration Set #1
Ratio 1 (dec)
Ratio 1 (hex) __ __ : __ __ : __ __ : __ __
RModSel1
RModSel0
AuxOutSrc1 AuxOutSrc0
LockClk1
LockClk0
FracNSrc
Modal Configuration Set #2
Ratio 2 (dec)
Ratio 2 (hex) __ __ : __ __ : __ __ : __ __
RModSel1
RModSel0
AuxOutSrc1 AuxOutSrc0
LockClk1
LockClk0
FracNSrc
Modal Configuration Set #3
Ratio 3 (dec)
Ratio 3 (hex) __ __ : __ __ : __ __ : __ __
RModSel1
RModSel0
AuxOutSrc1 AuxOutSrc0
LockClk1
LockClk0
FracNSrc
Global Configuration Set
AuxLockCfg
RefClkDiv1
RefClkDiv0
ClkOutUnl
LFRatioCfg
M2Cfg2
M2Cfg1
M2Cfg0
ClkIn_BW2
ClkIn_BW1
ClkIn_BW0