In this section you must select the file with the binary for the firmware to be updated.
The name of the file containing the binary must have a specific structure, because the
COMPACT
DC 3G
automatically determines whether the DLMS part or the PRIME part should be updated. The
structure must be as follows:
[flagID]_[UNESA_code]_[FW_DLMS or PRIME]_[FW version_no]�bin
Example:
CIR_DI_DLMS_v0209.bin or CIR_DI_PRIME_v2201.bin
Once the
Send
button is clicked, the update starts, as shown in
Figure 47:Update in progress screen�
The update can be cancelled at any time by clicking on the
Cancel
button.
If the cancellation is successful, the following screen is displayed
Figure 48:Cancellation successful screens�
5�6�- METERS MENU: CYCLES TEST
, you can change the parameters that determine the cyclical readings that
analyse the network status and functionality.
Figure 49:Cycles test�
With these test cycles you can find out the percentage of communications made over a certain period.
This allows you to determine the availability of each of the energy meters over a time period.
It is also possible to read or change any energy meter parameters.
We do not recommend activating cycles while other communications are in progress, such as tasks or
firmware updates.