– 7 –
SET THE OUTPUT VOLTAGE AND PRESETTING CURRENT
LIMITING VALUE (CC)
Push the knobs on time to check the preset voltage and current
level. Push again the knobs until the decimal place which you want
to adjust. Notice the selected decimal place will flash that mean
ready for adjustment. Turn the knobs to adjust your desired value.
To check the preset voltage and current level, just turn the knobs
lightly in any direction or just push the knobs on time.
CONNECTION AND OPERATION PROCEDURE
1. After checking with the rating label plug in to AC mains.
2. Switch on the power supply and the LCD display should be on at
the same time.
3. The (CV) icon should be shown on the display.
4. Turn to current volume knob "5"to maximum clockwise if you
do not require lower Current limiting value, otherwise do the
preset the (CC) limiting procedure.
5. Set your desired output voltage and then turn off the output
terminal by push button "6."
6. Connect to your load positive to positive and negative to nega-
tive.
7. Turn on the output terminal again and check if display shows
(CV).
8. If display shows (CC), either your preset current limiting value
is too low or your load requires more voltage and current. You
need to re-access the voltage and current requirement of your
load and increase the voltage or current accordingly until (CV)
appears.