Your Circuit-Test DMR-3600 Digital Multimeter incorporates the latest tech-
nology providing you with a feature packed instrument. With it you can
measure a wide range of voltages, current, inductance, capacitance and
resistance in the lab, shop, car and home. This meter has been designed for
the Electrician, Technologist, Hobbyist and Educational Institutions.

FEATURES

Inductance 

- measure inductance from 1

µ

H to 40H

Capacitance

 - test capacitors up to 400

µ

F

Frequency - 

display frequency to 4MHz

Continuity Buzzer 

- easily check for continuity.

Diode Check 

- test diodes and other semiconductors for open & short circuits.

HFE Test - 

displays DC current gain of Transistors

Heavy Duty & Safe 

- designed to meet UL1244 & IEC1010 safety require-

ments.

!

 WARNING

1.

Always start with the power off. Set the range switch to the correct setting
before making any measurements.

2.

Do not operate the unit unless the case is completely closed.

3.

Disconnect test leads from equipment before removing the battery or fuse.

4.

Never connect unit to AC or DC powered circuits when the range switch is
set to resistance, diode check or continuity ranges.

5.

To safeguard against electrical shock or damage to instrument, never
connect it to more than 600V DC or 600V AC between input jacks and
ground when measuring low energy circuits or 250VAC / 250VDC when
measuring high energy circuits.

6.

When using the test probes always keep your fingers behind the finger
guards on the probes. Never touch the exposed probe tip.

7.

Always inspect the instrument, test leads and other accessories for damage
prior to use.

8.

Disconnect the live/positive test lead prior before disconnecting the com-
mon/negative test lead.

9. Read this instruction manual carefully and completely before using.

!

 SAFETY PRECAUTIONS

This meter is not recommended for high voltage industrial use; for example,
do not use for measurements on 440VAC or 600VAC industrial power mains.
The unit is intended for use with low energy circuits to 600VDC / 600VAC or
high energy circuits to 250VAC / 250VDC only.

Содержание DMR-3600

Страница 1: ...OWNER S MANUAL Digital Multimeter DMR 3600 CIRCUIT TEST ELECTRONICS LTD A Division of R P Electronic Components Ltd Burnaby BC Canada V5C 5Y1 www circuittest com...

Страница 2: ...letely closed 3 Disconnect test leads from equipment before removing the battery or fuse 4 Never connect unit to AC or DC powered circuits when the range switch is set to resistance diode check or con...

Страница 3: ...utoranging on Frequency Polarity Automatic minus sign indicates for negative polarity Measuring Rate 2 5 times second Input Impedance 10 M DCV ACV Operation Temp 0 to 45 C Storage Temp 15 to 50 C Fuse...

Страница 4: ...C 400mV ranges 1000VDC 750 VAC 4 40 400 1000 750V ranges Current 0 5A 250 V Fuse for 40m 400mA ranges 10A 600 V Fuse for 10A range Maximum 60 seconds Resistance 500VDC 500VAC Capacitance 3VDC 3VAC rms...

Страница 5: ...o not connect to the circuit for more than 60 seconds and wait 10 minutes between 10A meas urements 3 1 PlugtheredtestleadintothemAjackandtheblacktestleadintotheCOM jack If the current being measured...

Страница 6: ...to the circuit being measured and disconnect test leads NOTE If changing range switch to or from the 10A position first disconnect power and test leads from the circuit being tested Repeat the above...

Страница 7: ...to 7 1 Plug the red test lead into the V jack and the black test lead into the COM jack 7 2 Set the range switch to the setting 7 3 Connect the probes to the device you want to test Note the meter rea...

Страница 8: ...t the capacitor leads are inserted into opposing sockets 10 3 Read the displayed capacitor value 11 INDUCTANCE MEASUREMENT 11 1 SettherangeswitchtothedesiredHInductancesetting Ifyouareunsure of the va...

Страница 9: ...connectorandreplacewithanew9Vbattery 13 5 Replace the cover and cover screws 14 FUSE REPLACEMENT WARNING Disconnect both test leads from any equipment before removing back cover Do not use the meter w...

Страница 10: ...xplana tion of the defect to In Canada Circuit Test Electronics A Division of R P Electronic Components Ltd 2060 Rosser Ave Burnaby BC V5C 5Y1 Any product which has been subjected to misuse or acciden...

Отзывы: