Frequency Measurements 

1. Set the Function/Range switch to the Hz position. 
2.  Connect  the  red  test  lead  to  the  DCV-DIODE-Hz  “+” 

jack and the black test lead to the DCV-DIODE-Hz “

” 

jack. 

3. Connect the test leads to the point of measurement and 

read the frequency from the display. 

 

Capacitance 

1. Discharge capacitors before trying to measure it. 
2. Set the Range to the desired F range. 
3. Insert the leads directly in to socket or test leads sockets. 
4. Never apply an external voltage to sockets or damage to 

the meter may result. 

5. Read the capacitance directly from the display. 

Note: In lower range 200pF, 2nF subtract residual offset 

reading from result with test leads opening

 

 

Resistance 

1. Set the Range to the desired “

Ω

” resistance range. 

2. Never apply an external voltage to the sockets or dam-

age to the meter may result. 

3. Insert the leads directly in to socket or test leads sockets. 
4. Read the Resistance directly from the display. 

WARNING 

The accuracy of the functions might be slightly affected, 

when exposed to a radiated electromagnetic field 

environment, e.g., radio, telephone or similar. 

 

Inductance 

1. Set the Ranges to the desired H range. 
2. Never apply an external voltage to the sockets damage 

to the meter may result. 

3.  Insert  the  inductor  leads  directly  into  sockets  or  test 

leads sockets. 

4. Read the inductance directly from the display. 

Note:  In  lower  range  200µH,  2mH  subtract  residual 

offset  reading  from  result  with  test  leads  being 
shorted.

 

MAINTENANCE 

WARNING 

Remove test leads before changing battery or fuse or 

performing any servicing. 

 
Battery Replacement 

Power  is  supplied  by  a  9  volt  “transistor”  battery. 

(NEDA  1604  IEC  6F22).  The  “

”  appears  on  the  LCD 

display when replacement is needed. To replace the battery, 
remove the two screws from the back of the meter and lift 
off the battery case. Remove the battery from battery con-
tacts. 

 

Fuse Replacement 

If no capacitance and inductance measurements are pos-

sible,  check  for  a  blown  overload  protection  fuse.  For 
access  to  fuses,  remove  the  two  screws  from  the  back  of 
the  meter  and  lift  off  the  battery  case.  Replace  F1  only 
with the original type 0.1A/250V, fast acting fuse. 

 

Cleaning 

Periodically wipe the case with a damp cloth and deter-

gent, do not use abrasives or solvents. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 