5.  Read the temperature in the display. The digital reading will indicate the 

proper decimal point and value.

WARNING: 

To avoid electric shock, be sure the thermocouple has been 

removed before changing to another measurement function

Non-Contact AC Voltage Measurements

WARNING:  

Risk of Electrocution. Before use, always test the Voltage 

Detector on a known live circuit to verify proper operation

1.  Touch the probe tip to the hot conductor or insert into the hot side of the 

electrical outlet.

2.   If AC voltage is present, the detector light will illuminate.

NOTE: 

  The conductors in electrical cord sets are often twisted. For best 

results, rub the probe tip along a length of the cord to assure placing 

the tip in close proximity to the live conductor.

NOTE: 

  The detector is designed with high sensitivity. Static electricity or 

other sources of energy may randomly trip the sensor. This is normal 

operation

MODE Button

To select DC/ACV, OHM/Diode/Continuity, °C/°F

MAX & MIN Recording Button

Press MAX/MIN to enter MIN, MAX recording mode (manual range only). 

Select  the  proper  range  before  selecting  this  mode  to  ensure  that  the 

MIN/MAX reading will not exceed the testing range. Press once to select MAX. 

Press again to select MIN and press and hold MAX/MIN button  to exit this mode.

Содержание DCL-620

Страница 1: ...USER S MANUAL Clamp on Multimeter True RMS AC DCL 620 CIRCUIT TEST ELECTRONICS www circuittest com...

Страница 2: ...Y NOTES Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set function switch OFF when the meter is not in use WARNINGS...

Страница 3: ...is to be stored for long periods Always discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can...

Страница 4: ...MODE button 11 LCD display 12 COM input jack 13 Positive input Jack AC Alternating current DC Direct currrent AUTO Autoranging REL Relative Diode test Continuity test HOLD Data Hold MAX Maximum readin...

Страница 5: ...digits 60 00 VDC 600 0 VDC AC Voltage 50 400Hz 6 000 VAC 1 8 8 digits 60 00 VAC 600 0 VAC Resistance 600 0 1 0 4 digits 6 000K 1 5 2 digits 60 00K 600 0K 6 000M 2 5 3 digits 60 00M 3 5 5 digits Capac...

Страница 6: ...ounts LCD AC Current bandwidth 50 400Hz AAC AC Voltage bandwidth 50 400Hz VAC Operating Temperature 41 to 104 F 5 to 40 C Storage Temperature 4 to 140 F 20 to 60 C Operating Humidity Max 80 up to 87 F...

Страница 7: ...600A range 2 If the range of the measured is not known select the higher range first then move to the lower range if necessary 3 Press the trigger to open jaw Fully enclose one conductor to be measur...

Страница 8: ...ad the resistance on the LCD display Diode and Continuity Measurements 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jac...

Страница 9: ...icate Hz in the display 4 Insert the black lead banana plug into the negative COM jack and the red test lead banana plug into the positive Hz jack 5 Touch the test probe tips to the circuit under test...

Страница 10: ...e detector light will illuminate NOTE The conductors in electrical cord sets are often twisted For best results rub the probe tip along a length of the cord to assure placing the tip in close proximit...

Страница 11: ...ents For measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The Auto display indicator will turn off 2 Press the RANGE button to step thr...

Страница 12: ...riginal purchaser that this product be free of defect in material or workmanship for a period of 2 years from the date of purchase Any product which has been subjected to misuse or accidental damage i...

Отзывы: