Operating instructions
1. Connect the iron to the base station
2. Connect the power and switch on. The iron will heat.
3. Rotate the temperature adjustment dial on the front panel to adjust the
temperature to the desired setting.
Three Channel Storage Feature:
The unit is equipped with the ability to store 3 separate heat settings.
To Store Temperature Settings
Press the CH1 button to display the
①
icon on the control panel. Adjust
the main dial to set the desired temperature on the display. After 6
seconds at the set temperature, the unit automatically stores the
temperature value to CH1. Set CH2 and CH3 in the same way to store 3
quick access settings.
Fahrenheit / Celsius Conversion:
The user may choose to display either Celsius or Fahrenheit.
Press temperature dial until °C / °F icon flashes in the display.
Rotate the temperature adjustment dial to switch between
Fahrenheit / Celsius (left rotation adjustment for °C, right rotation
adjustment for °F).
After setting, the characters flash seven times before returning to
work mode. You may also press the temperature dial again to
confirm your setting.
Iron Sleep Function Settings:
Press the temperature dial twice, the display panel flashes L00.
Rotate the temperature adjustment dial to set the iron sleep time
(Range: 0-99 minutes, 00 for no sleep).
The time set will flash 7 times before returning to work mode. You
may also press the dial again to confirm your setting and cycle
through to set the automatic shutdown feature.
NB.: During sleep mode, the soldering iron temperature is
automatically lowered to 200°C. Simply move the iron handle to
restore the settings that were active prior to sleep mode activation.
5. To Set the Automatic Shutdown Feature:
Press the temperature dial 3 times until the display flashes “P00”.
Rotate the main dial to set automatic shutdown time (range 0-99
minutes, - set 00 to cancel automatic shutdown).
The display will flash seven times before returning to work mode.
You may also press the main dial again to confirm your selection.
6. To Set the Temperature Correction Feature:
Press the main dial 4 times. The display will flash “00”.
Rotate the main dial to set the iron temperature (correction range:
±50°C).
The display will flash seven times before returning to work mode.
You may also press the main dial again to confirm your selection
NB: The CSI PREMIER 75W is calibrated at the factory. For most
applications, there should be no requirement to re-calibrate the unit. This
feature should only be required if the user wishes to re-calibrate the
output due to the use of a different tip style or operating environment, or if
there is a discrepancy in output after heating element / iron replacement.
Limited Warranty Statement
This unit has a limited warranty of 1 year from the date of the original
purchase receipt. Excluded from this warranty are any consumables such
as soldering tips and heating elements. Should the main body fail during
the warranty period, Circuit Specialists wil
l, at its’ option, repair or replace
the damaged unit. This warranty applies only to manufacturing defects.
Damage caused by misuse, physical trauma etc. is excluded. To receive
warranty service, the unit must be returned to the point of purchase. The
end user will be responsible for the shipping costs (if any). Circuit
Specialists will be responsible for the cost of returning the repair or
replacement. Please check with the appropriate retailer for specific return
procedures.