CIRCUIT DESIGN SLR-434M Скачать руководство пользователя страница 4

OPERATION GUIDE

OG_SLR-434M_v10e

Circuit Design, Inc.

4

3. Specifications

*All values are when the antenna connector is the 50 Ω terminal. 

*Unless otherwise indicated, specified values are at a temperature of 25 °C ± 5 °C.

Item

Specification

Applicable standard

EN 300 220

Frequency channels

433.075 MHz to 434.7750 MHz (12.5 KHz step, 137 channels)

Frequency deviation

± 2 ppm or less

Antenna power

10 mW or less

Communication

method

Half-duplex or one-way

Radio wave format

F1D

Modulation*

1

LoRa or Binary FSK

Radio communication

speed

15 to 245 bps (Real speed using LoRa, depends on the spreading
factor)
4800 bps (FSK)

Receiver spurious

radiation

-54 dBm or less

Receive sensitivity*

2

-133 dBm (LoRa 128 chip), -115 dBm or less (FSK),

PER 1% with the user data of 45 bytes or less

Carrier sensing

threshold

-96 dBm (LoRa)

Operating temperature

range

-30 to +70°C

Storage temperature

range

-30 to +80°C

Recommended

operating voltage range

3.5 to 5.0 V

Warranted operating

voltage range

3.3 to 5.5 V

Operating current

Tx: 29 mA (Typ)

Rx: 17 mA (Typ) (Supply power = 5 V)

Antenna provided 

1/4λ whip antenna (L=170 mm, gain 2.14 dBi or less)  

Antenna connector

SMA

Interface

UART port

External dimensions

40 × 29 × 6.2 mm (±0.4) (Not including the antenna and
projections)

Weight

13 g

Soldering conditions

Hand soldering
Soldering iron temp.: 350°C within 3 seconds

Note:

*1:

When using the LoRa mode and moving around, the impact of the Doppler effect may make

communication impossible.

*2: Receive sensitivity performance is affected by the power supply and surrounding noise levels (floor noise

level). The approximate minimum level at which reception is possible is noise level +10 dB for FSK and -10
dB for LoRa. (Example: When the floor noise level is -110 dBm, reception is possible with FSK to about -
100 dBm and with LoRa to about -120 dBm). You can check the floor noise level with the @RA command
and the evaluation application (air monitor).

Содержание SLR-434M

Страница 1: ...sign Inc Embedded low power radio modem SLR 434M Smart RF modem Operation Guide Version 1 0 Jan 2018 Circuit Design Inc 7557 1 Hotaka Azumino Nagano Japan Tel 0263 82 1024 Fax 0263 82 1016 e mail info...

Страница 2: ...nts 1 OVERVIEW 3 2 FEATURES AND APPLICATIONS 3 3 SPECIFICATIONS 4 4 PART NAMES AND FUNCTIONS 5 5 CONNECTION EXAMPLES FOR DIO TERMINALS 8 6 APPEARANCE 9 7 COMMUNICATION FREQUENCY TABLE 10 8 UART PORT C...

Страница 3: ...to 8 contacts 2 Features and applications Features RED compliant Plan Ultra long distance communication using the LoRa mode Enhanced resistant to city noise and longer range compared with our earlier...

Страница 4: ...orage temperature range 30 to 80 C Recommended operating voltage range 3 5 to 5 0 V Warranted operating voltage range 3 3 to 5 5 V Operating current Tx 29 mA Typ Rx 17 mA Typ Supply power 5 V Antenna...

Страница 5: ...bps Bits 8 Parity none Stop 1 Serial data Transmitter RXD I Serial data Receiver RTS O The UART control terminal When RTS Hi do not input data Hardware flow control output terminal CTS I The UART cont...

Страница 6: ...LORA CMD MODE or FSK CMD MODE is output from the TXD terminal after the device restarts After reset and restart the device is initialized to the setting value saved by adding W to commands such as ch...

Страница 7: ...he transmission monitor LED connection terminal Lo Active When a radio wave communication signal is sent this terminal changes to Lo GND The ground terminal VCC The power supply terminal Connect to a...

Страница 8: ...nal level inverted via a transistor Using long wiring between the DIO terminal and the switch may cause malfunction due to noise In that case take measures such as externally pulling down with a resis...

Страница 9: ...6 Appearance Note When designing circuit boards take care to ensure space for the SMA connector dimensions and screw fixture for connecting the antenna If the underside of the connector is also the su...

Страница 10: ...4F 434 0625 12 0C 433 2250 46 2E 433 6500 80 50 434 0750 13 0D 433 2375 47 2F 433 6625 81 51 434 0875 14 0E 433 2500 48 30 433 6750 82 52 434 1000 15 0F 433 2625 49 31 433 6875 83 53 434 1125 16 10 43...

Страница 11: ...34 000 MHz for shipment If you intend to use several SLR 434M units in the same area use a channel plan that takes into account radio interference due to third order intermodulation Circuit Design pro...

Страница 12: ...D setting Equipment Target station Group ID EI DI GI 0A With Equipment ID EI 0A Sets the Equipment ID local station to 0A Sets the ID for identifying each radio station and the other party in communic...

Страница 13: ...fter command value data optional add the line feed code CR LF If you omit value data you can check the content of the current settings If the optional W is added the setting value is saved and it beco...

Страница 14: ...cuits and reverse connections may result in overheating and damage and must be avoided at all costs Ensure that the power supply has been switched off before attempting any wiring work The case is con...

Страница 15: ...vision History Version Date Description Remark 0 91 Feb 2017 Provisional Edition 1 0 Jan 2018 The copyright of this manual belongs to Circuit Design Inc Reproduction duplication or modification of par...

Отзывы: