49
Value
Description
ID
Charge Point identifier
Cache max. size
Maximum size of the
Authorization Cache, that autonomously
maintains a record of previously presented identifiers that have
been successfully authorized by the Central System.
It can be viewed accessing to the following URL:
http://<IP>:8080/services/cmd/dump_cache.xml
Use OCPP time
synchronization
YES:
Synchronization of date and time -> Enabled.
NO:
Synchronization of date and time -> Disabled.
*NOTE:
Date and Time is sent from backend on each heartbeat
response.
Energy for Start/
Stop transaction
PARTIAL:
Consumed value of energy by the vehicle sent between
start and stop.
TOTAL:
actual count of the total accumulated energy meter sent
between start and stop.
Energy for
MeterValues
PARTIAL:
Sends partial energy consumption while vehicle is
charging.
TOTAL:
sends the actual count of the total accumulated energy
meter.
User confirmation
required on remote
start
ON:
user confirmation needed to proceed with a remote start (i.e.
touch the screen)
OFF:
user confirmation NOT needed to proceed with a remote
start