Страница 2: ... Operating the Five Line Station 15 Troubleshooting 16 Specifications 17 Warranty 18 Disclaimer 18 Warning 18 Service Telephone Number 18 Feedback 18 Guardian Product Return 19 Typical Installation 20 Cleaning Tips for Guardian Communication Products 20 Table of Figures Figure 1 Features All Options Shown 7 Figure 2 Dimensions PTR PPR 7 Figure 3 Dimensions PTA PPA 8 Figure 4 Harness Connections 8 ...

Страница 3: ...where the door of the enclosure would prevent the sensor from picking up the ambient noise and for other applications where an ambient noise sensor is not required The models that do have ambient noise sensors on the faceplate can replace any other module either on a temporary or permanent basis This is a great convenience and cost saving feature since only one spare module needs to be stocked and...

Страница 4: ...mbient noise sensor P5505 PTA Amplifier module P5506 PPR Handset module with ambient noise sensor and 16 Pin Harness for Gaitronics enclosure P5507 PPR Handset module with ambient noise sensor headset connector and 16 Pin Harness for Gaitronics enclosure P5508 PPR Handset module with 16 Pin Harness for Gaitronics enclosure P5509 PPR Handset module with 16 Pin Harness and ambient noise sensor kit f...

Страница 5: ...lifier Module P006151 Faceplate Amplifier Module Without Ambient Noise Sensor P005794 Connector Harness 16 Pin P006070 Connector Harness 24 Pin Page Talk Options and Accessories Housings P5520 Indoor standard housing P5521 Indoor desk amplifier housing P5522 Outdoor ambient noise housing P5523 Outdoor housing Switch And Access Plates P5530 Five line switch plate P5531 Single line access plate Kits...

Страница 6: ...eplate System Indicator LED indicates if handset is off hook Handset page switch on handset noise canceling dynamic microphone electronic hook switch provides durability Headset optional plug in headset Speaker Muting a jumper on the circuit board selects muting of the associated speaker to avoid acoustic feedback Controls speaker volume internally and externally accessible ambient noise level mon...

Страница 7: ...Guardian Telecom Installation and Operation Models PTR PTA PPR PPA Page 7 Figure 1 Features All Options Shown Figure 2 Dimensions PTR PPR ...

Страница 8: ...Guardian Telecom Installation and Operation Models PTR PTA PPR PPA Page 8 Figure 3 Dimensions PTA PPA Figure 4 Harness Connections ...

Страница 9: ...stallation and Operation Models PTR PTA PPR PPA Page 9 Figure 5 PTR in Guardian Indoor Housing Figure 6 PTR in Guardian Outdoor Housing Figure 7 PPR in Gaitronics Outdoor Housing Figure 8 PPR in Gaitronics Indoor Housing ...

Страница 10: ... J2A J3A 2A Channel 2 Violet 18 AWG J2A J3A 2B L Brown Violet J2A J3A 3A Channel 3 Blue 18 AWG J2A J3A 3B L Brown Blue J2A J3A 4A Channel 4 Brown 18 AWG J2A J3A 4B L Brown Brown J2A J3A 5A Channel 5 Yellow 18 AWG J2A J3A 5B L Brown Yellow Group Muting of J2A J3A Mute Orange 18 AWG Loudspeakers J2A J3A Park Spare Conductor Special Order n a Extra Red 12 AWG Note Channels 2 to 5 connections remain e...

Страница 11: ...ING high voltages are present in this equipment when it is connected to the power source Disconnect power to the station Ensure that the module is set up for the correct voltage Tip check the label on the main circuit board cover Remove the existing module by undoing the four screws and gently pulling the module loose from the connector The Guardian replacement module requires an adapter harness t...

Страница 12: ... Group Muting Insert the faceplate ensuring that the connector is properly seated Tighten the four screws Apply power to the system Wait at least 20 seconds then adjust speaker volume to the desired level using the potentiometer accessible through the screw hole in the faceplate Use a small flat tip screwdriver to make the adjustment Note Adjust speaker volume while ambient noise at the station is...

Страница 13: ...rtable level when the ambient noise is at a minimum The Ambient Noise Monitor Adjustment Control determines how the speaker volume tracks the ambient noise That is if the speaker is not loud enough with a high ambient noise the control can be adjusted to increase the volume Alternatively if the speaker is too loud with a high ambient noise the control can be adjusted to decrease the volume It is u...

Страница 14: ... its mute jumper in the off position will not be muted when a paging call is made from any station in the group including the associated station Note Paging calls originating from stations outside the group will be heard regardless of the position of the Mute jumper If it is desired to bypass a station in a group connect the group paging wires to the PARK terminals of that station EXAMPLE OF GROUP...

Страница 15: ... Line Place the handset back on the cradle Check to ensure that the off hook detector LED is out Operating the Five Line Station Initiating a Call Note There are five talk lines on the five line station Remove the handset Select a free line using the Line selector Broadcasting a Page Press and hold the Page button on the handset Note Continue holding down the Page button while broadcasting the pag...

Страница 16: ...mbly is loading the lines properly 33 Ohms for Talk lines and 33 to 133 Ohms for Page lines Sidetone Adjust sidetone level control on circuit board Station Stays On or Off Hook LED Status Indicator On 1 Ensure power is being supplied to the station 2 Test the proximity switch in the handset receiver cradle by moving a small permanent magnet over the area while listening on the handset for the line...

Страница 17: ...PONSE 250 4000HZ DISTORTION 1 MAXIMUM THD 1000HZ 10WATTS INPUT IMPEDANCE 200K OHMS NOMINAL LOAD IMPEDANCE 4 TO 16 OHMS NOT LESS THAN 8 OHMS FOR CONTINUOUS SERVICE ENVIRONMENTAL WEATHER TIGHT ENCLOSURE GASKET DUST TIGHT ENCLOSURE GASKET MECHANICAL FACEPLATE AND SWITCH PLATE STAINLESS STEEL PTR PPR DIMENSIONS H X W X D 8 1 8 X 8 1 8 X 5 6 INCHES 206 X 206 X 133 165 MM PTA PPA DIMENSIONS H X W X D 8 ...

Страница 18: ...ages may be present in this product ensure that power is removed before installing performing maintenance or making repairs Service Telephone Number 1 800 363 8010 Toll Free In North America Guardian Telecom provides a customer service telephone number which is toll free within North America If you need assistance when installing or operating this product please call the toll free telephone number...

Страница 19: ...calling the service telephone number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation returned with the product In addition to the RMA number shipping documents should include name address and telephone number of the owner along with contact information for the person responsible fo...

Страница 20: ...ot spray the Product directly Spray the cleaner on a soft cloth then wipe the surface Pre treated cloths like those used for eyeglasses or cameras may be used to clean the Product Remoistened novelettes may also be used however avoid those containing lanolin or aloe as they will leave a slippery residue The handset and surface of the Product may be cleaned with disinfectants used for general clean...

Страница 21: ...Guardian Telecom Installation and Operation Models PTR PTA PPR PPA Page 21 Notes Model No Part No Serial No Date of Purchase ...

Страница 22: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 23: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 24: ...dian Telecom Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail mailto sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom 2018 ...

Отзывы: