Circa Enterprises Guardian P5520 Скачать руководство пользователя страница 8

Guardian Telecom 

Installation and Operation 
Page/Talk Indoor Housing 

 

Page 8 

 

 

 

Figure 7 - Wiring 

 

Assignment 

Designation 

Description 

Jacket 

Color 

Stripe 

Color 

Wire 

Gauge 

System Power 

J4A/J5A 

HOT 

Black 

 

14 AWG 

 

J4A/J5A 

COM 

White 

 

14 AWG 

 

J4A/J5A 

GND 

Green 

 

14 AWG 

Ambient Noise 

J6A 

MIC + 

n/a 

n/a 

n/a 

Microphone 

J6A 

MIC - 

n/a 

n/a 

n/a 

Speaker 

J7A 

SPK + 

n/a 

n/a 

n/a 

 

J7A 

SPK - 

n/a 

n/a 

n/a 

Page Line 

J2A/J3A 

PA     Page Line 

Blue 

Red 

18 AWG 

 

J2A/J3A 

PB             " 

Red 

Blue 

Channel 

J2A/J3A 

1A     Channel 1 

Red 

 

18 AWG 

 

J2A/J3A 

1B             " 

L. Brown 

Red 

 

J2A/J3A 

2A     Channel 2 

Violet 

 

18 AWG 

 

J2A/J3A 

2B             " 

L. Brown 

Violet 

 

J2A/J3A 

3A     Channel 3 

Blue 

 

18 AWG 

 

J2A/J3A 

3B             " 

L. Brown 

Blue 

 

J2A/J3A 

4A     Channel 4 

Brown 

 

18 AWG 

 

J2A/J3A 

4B             " 

L. Brown 

Brown 

 

J2A/J3A 

5A     Channel 5 

Yellow 

 

18 AWG 

 

J2A/J3A 

5B             " 

L. Brown 

Yellow 

Group Muting of 

J2A/J3A 

Mute 

Orange 

 

18 AWG 

Loudspeakers 

J2A/J3A 

Park 

 

 

Spare Conductor 
(Special Order) 

n/a 

Extra 

Red 

 

12 AWG 

Note: 

Channels 2 to 5 connections remain empty for single Talk Line hookup. 

If this station is in a Group Muting series, but is not to be muted when paging calls are made from 
other stations in the group, connect the wires assigned to this function to the Park terminals. 
 

Figure 8 - Electrical Connections 

 

 

Содержание Guardian P5520

Страница 1: ...Ph 403 258 3100 email info guardiantelecom com www guardiantelecom com Page Talk Indoor Housing Installation Operation P5520 P5521 P006114 Rev C 171030 10 30 2017 12 37 PM ...

Страница 2: ...urn 13 Page Talk System Models and Options 14 Typical Installation 15 Table of Figures Figure 1 Features With Optional Desk Set Connector 4 Figure 2 Dimensions 5 Figure 3 Mounting 5 Figure 4 Wiring Photo 6 Figure 5 Installation Photo 7 Figure 6 Crossbar Assembly Photo 7 Figure 7 Wiring 8 Figure 8 Electrical Connections 8 Figure 9 Maximum Speaker Cable Runs to Limit Volume Loss to 1dB 9 Package Con...

Страница 3: ...ation of a connector in the event that the station is used as a desk set amplifier Features Construction 16 gauge steel zinc dichromate plated and powder coated Cable Entrances knockouts are provided at convenient locations Mounting kits are available for pole mounting and flush mount installations hole spacing for wall mounting is industry standard Connectors removable screw and plug Combicon con...

Страница 4: ...Guardian Telecom Installation and Operation Page Talk Indoor Housing Page 4 Figure 1 Features With Optional Desk Set Connector ...

Страница 5: ...Guardian Telecom Installation and Operation Page Talk Indoor Housing Page 5 Figure 2 Dimensions Figure 3 Mounting ...

Страница 6: ... Wiring Photo Note Total impedance on the amplifier circuit should not be less than eight ohms for continuous operation such as background music and not less than four ohms for intermittent operation such as paging Suitable resistors can be wired in series or in parallel with speakers to maintain an acceptable impedance ...

Страница 7: ...Guardian Telecom Installation and Operation Page Talk Indoor Housing Page 7 Figure 5 Installation Photo Figure 6 Crossbar Assembly Photo ...

Страница 8: ... J3A 1B L Brown Red J2A J3A 2A Channel 2 Violet 18 AWG J2A J3A 2B L Brown Violet J2A J3A 3A Channel 3 Blue 18 AWG J2A J3A 3B L Brown Blue J2A J3A 4A Channel 4 Brown 18 AWG J2A J3A 4B L Brown Brown J2A J3A 5A Channel 5 Yellow 18 AWG J2A J3A 5B L Brown Yellow Group Muting of J2A J3A Mute Orange 18 AWG Loudspeakers J2A J3A Park Spare Conductor Special Order n a Extra Red 12 AWG Note Channels 2 to 5 c...

Страница 9: ...re and dust See Figure 3 Mounting If this is a new installation use the template provided or the housing itself to locate and drill holes for mounting screws See Insert Template Secure the unit to the wall Ensure that none of the electrical connection circuits are live Bring cable s into the enclosure through the conduit entrance s and attach individual wires to the Combicon connector s Attach the...

Страница 10: ...hen a paging call is made from any station in the group including the associated station Note Paging calls originating from stations outside the group will be heard regardless of the position of the Mute jumper If it is desired to bypass a station in a group connect the group paging wires to the PARK terminals of that station EXAMPLE OF GROUP MUTING If the Group Mute Signal Conductors are attached...

Страница 11: ...US AREAS WHEN INSTALLED IN CONFORMANCE WITH CSA CERTIFICATE OF COMPLIANCE 1289924 LR65547 SEE MANUAL NUMBER P006257 FOR DETAILS Installation Cable Listing Part No Description Part No Description P006183 2 Conductor 18AWG Armored Speaker P005863 8 Conductor Armored Single Line System P006184 2 Conductor 18AWG Standard Speaker P005916 8 Conductor Standard Single Line System P006217 4 Conductor 18AWG...

Страница 12: ...tages may be present in this product ensure that power is removed before installing performing maintenance or making repairs Service Telephone Number 1 800 363 8010 Toll Free in North America Guardian Telecom provides a customer service telephone number which is toll free within North America If you need assistance when installing or operating this product please call the toll free telephone numbe...

Страница 13: ... calling the service telephone number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation returned with the product In addition to the RMA number shipping documents should include name address and telephone number of the owner along with contact information for the person responsible f...

Страница 14: ...PTI P5980 Line Balance Assembly LBU Alarm Tone Generator AG 17 P5960 With Relay P5970 Without Relay Acoustic Booths P9010 AB100 Aluminum or Steel full size P9035 AB1000 Glass Reinforced Plastic hood P9029 AB2000 Glass Reinforced Plastic full size Cable 2 Conductor 18AWG Industrial Armored Speaker Cable 2 Conductor 18AWG Industrial Standard Speaker Cable P006217 4 Conductor 18AWG Industrial Armored...

Страница 15: ...Guardian Telecom Inc Installation and Operation Page Talk Indoor Housing Page 15 Typical Installation ...

Страница 16: ...Guardian Telecom Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom 2017 ...

Отзывы: