12
WARNING!
• The electrical installation and repairs may only be performed by a specialist in
accordance with the applicable regulations and national standards.
NOTE!
• The device plug must be easily accessible so that you can unplug it if required, thereby
disconnecting the toilet from the power.
• The connection cable must be laid so that it does not come in contact with sharp edges.
• Changes to the internal electrical installation or the connection cable must be per-
formed by a professional tradesman or a similarly qualified person in order to prevent
safety hazards.
• It may be necessary to protect the receptacle with a GFCI. Ensure that all installations
are in accordance with national electrical code.
2.6 ELECTRICAL SPECIFICATIONS AND REQUIREMENTS
The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, earthed
circuit that is protected by a properly sized circuit breaker. The proper voltage, frequency and amperage are
listed in this manual, and on the product rating plate on the back of the toilet. Please note: This toilet requires a
12V 4A DC supply. If you require to operate it from a 240V AC power point (GPO) please request the approved
power supply from your dealer.
Power requirements
INPUT
CURRENT
FUSE
12V DC (11 – 14.4V)
4 A
10 A
Power consumption
HIBERNATION MODE
STANDBY MODE
INCINERATING MODE
0.005 A
0.09 A
1.3 A
Connection polarity
CROSS SECTION
POSITIVE
NEGATIVE
14 AWG
Red
Black
The respective negative and positive cables of the DC connection must not be joined to one another in a
camper, as this can cause electrical interference and damage to electrical components. The 12V supply must
be connected on its own circuit direct to the battery, with a 10 A fuse at the start of the circuit. Use the 12V wire
guide to calculate the correct cable size according to the cable length.
When connecting the toilet to the mains DC power, take the following into consideration:
•
Make sure the cable has sufficient current rating for the expected load in the circuit, including a margin of
safety.
• Make sure the cable cross section is dimensioned for the intended cable run length, and that the cable will
not cause the voltage to drop.
• Always check the polarity of the cables before connecting as reverse polarity connection is not covered under
warranty.
12V WIRING GUIDE
Amps
0-8 feet
0-2.5 m
9-15 feet
2.5-4.5 m
16-30 feet
4.5-9 m
31-45 feet
9-14 m
4
16 AWG
12 AWG
10 AWG
8 AWG
Содержание FREEDOM GAS NA
Страница 62: ...32...
Страница 63: ...FRAN AIS 33...