Cimarron ARCONTROL BMS Скачать руководство пользователя страница 2

5

Y+  R-

      

POWER

 

        

VALVE

        

OUTRET

       

RS485

        

A    B

       

TC1

        

Y+  R-

      

TC2

        

VLV B

DIN
GND
PS3

GND
PS2
GND

PS1
PWR

A

B PWR GND

MODULE PORT

IN+
IN-
GND
R-

B-

A+

Y+
GND

Y+
R-

THERMO-

COUPLE 

PORT

RS485 

PORT

ALARM 

OUTPUT

DOUT-

DOUT-
AUXIO

GND

DOUT+

GND

OPN-G

GND

CLS-R

OPN-G

GND

CLS-R

MAIN 

VALVE

BATTERY-IN

GND

SOLAR

GND

PWR-OUT

BATTERY-OUT

PILOT 

VALVE

POWER 

PORT

DIGITAL 

OUTPUTS

GND GND

GROUND

GND GND

DIGITAL

INPUTS

TRANS-

DUCER 

PORT

TC2

TC1

MAIN

VLV A

PILOT

Permissive

-

Proof of Closure

-

PS2

 

PS1

ARControl BMS

Thermocouple  1

R- 

Y+

Thermocouple  2

R- 

Y+

Alarm

+

Independent

Process Valve

+

-

Pilot Status

+

-

-

+

Process 1 Valve 

Process 2 Valve

-

+

Pilot Valve 

Process 3 Valve

-

+

Transducer

Port

GND 

B-

A+

Modbus 

RS-485

PWR 

+

-

GND

Maintenance & 

Service

    

Contact Cimarron Energy, Inc. 

for information in regard to 

maintenance, parts, or service 

at 1-844-746-1676 or visit 

www.cimarronenergy.com

15.  Install the Process 1  

    Valve upstream of the 

    burner and wire the  

    Process  1 Valve to the  

    Process 1 Valve output  

    of the ARControl.
16.  Connect the power  

    source to the power and  

    ground terminal blocks.
17.  If using 

Pressure Control  

    (old SAU functionality  

    w/ Barksdale 8100-020),  

    navigate to 

SETTING  

    MENU > PROCESS 1, set: 

•  SOURCE to XDCR

•  LOGIC to ↑ ON ↓ OFF 

(HIGH ON LOW OFF)

•  HIGH LEVEL to 50

•  LOW LEVEL to 20

18.  If using the 

High- 

    temperature shutdown  

    feature, navigate to  

  

SETTING MENU > BMS  

    MODULE > TEMP LIMIT  

    to set the temperature.
19.  If using 

Temperature  

   Control (old Torch  

    functionality) (Image  

    1.2.2), navigate to  

  

SETTING MENU >  

    PROCESS 1, set:

•  SOURCE to TC BMS

•  LOGIC to ↑ OFF ↓ ON 

(HIGH OFF LOW ON)

•  HIGH LEVEL to high 

process temperature

•  LOW LEVEL to low 

process temperature

20.  Navigate to the 

START  

    (HOLD OK) menu entry  

    on the home screen  

    and hold the 

OK key for  

    at least a second. This  

    will start the ignition  

    sequence and process  

    control.

VLV B

DIN
GND
PS3

GND
PS2
GND

PS1
PWR

A

B PWR GND

MODULE PORT

IN+
IN-
GND
R-

B-

A+

Y+
GND

Y+
R-

THERMO-

COUPLE 

PORT

RS485 

PORT

ALARM 

OUTPUT

DOUT-

DOUT-
AUXIO

GND

DOUT+

GND

OPN-G

GND

CLS-R

OPN-G

GND

CLS-R

MAIN 

VALVE

BATTERY-IN

GND

SOLAR

GND

PWR-OUT

BATTERY-OUT

PILOT 

VALVE

POWER 

PORT

DIGITAL 

OUTPUTS

GND GND

GROUND

GND GND

DIGITAL

INPUTS

TRANS-

DUCER 

PORT

TC2

TC1

MAIN

VLV A

PILOT

Permissive

-

Proof of Closure

-

PS2

 

PS1

Transducer

Port

ARControl BMS

Thermocouple  1

R- 

Y+

Thermocouple  2

R- 

Y+

Alarm

+

Independent

Process Valve

+

-

Pilot Status

+

-

-

+

Process 1 Valve 

Process 2 Valve

-

+

Pilot Valve 

Process 3 Valve

GND 

B-

A+

Modbus 

RS-485

-

+

PWR 

+

-

GND

Image 1.1.1 · BMS pressure process control wiring diagram

Permissive IN

(jump closed 

if not in use)

To Pilot Igniter

Ignition 

Wire

Important!  

I/O board 

stickers. Replace 

when missing.

Stack/Bath

Source Gas

7

10

8

Pilot Status OUT 

(optional)

12 or 

24VDC 

Power IN

Modbus RS-485 

(optional)

ESD Valve

Source 

Gas

To Pilot

To Burner

Process 1 Valve

Pilot Valve

13

14

15

Image 1.1.2 · BMS temperature process control wiring diagram

Permissive IN

(jump closed 

if not in use)

Note: Wiring for the temperature process control is 

identical as the pressure process control (Image 1.1.1) 

except  the Transducer Port should be jumpered.

Modbus RS-485 

(optional)

5

Y+  R-

      

POWER

 

        

VALVE

        

OUTRET

       

RS485

        

A    B

       

TC1

        

Y+  R-

      

TC2

        