background image

©2015  Stewart  Filmscreen  Corporation

S

PECIFICATIONS (C

ONTINUED

)

Cima Above Ceiling

 Electri

S

creen: Owner’s  Manual

13

External LV Control            On-board channel (i.e. Up/Down) low 

voltage connection is designed to 

interact with dry contact keypad or 

third-party off-the-shelf switches

RS-232-C Control

     Optional Cima-Link Serial RS-232 

Package Upgrade includes a serial 

adapter that plugs anywhere onto the 

CS-Bus network line up 4,000 feet from 

the Cima screen

CIMA-LINK CONTROLLER PACKAGES OVERVIEW

Figure 5 shows example applications of the Cima-Link Controller 

Accessories (not included) for which the Cima Above Ceiling Electric

S

creen 

can be integrated with infrared remote, additional Cima screens, and 3rd 

party applications

Figure 5:

  Cima-Link Controller Package Interface

Power Requirements

   Domestic Version: 120vAC, 50/60 Hz,

 

International Version: 240vAC 50/60 

Hz

Safety

 ETL Listed.  Conforms to UL STD 325   

 (120v version)

Содержание Above Ceiling ElectriScreen

Страница 1: ...he Owner Installation Instructions Screen Care Maintenance TO T H E I N S TA L L E R B E S U R E T O L E AV E T H I S M A N U A L W I T H T H E O W N E R CFS 0115 Above Ceiling Electriscreen Owner s Manual ...

Страница 2: ... installed by a qualified electrician For supply connections use wires rated for at least 75 C Use Copper or Aluminum conductors For indoor use only Do not connect Low Voltage to Line Voltage Power Earth Ground terminal connection must be made as shown in wiring diagrams Article 725 54 a 1 Exception No 3 NEC or Canadian CE Code Handbook Rule 16 212 Sub rule 4 requires segregation between line volt...

Страница 3: ...21 Step 2 Electrical Hookup 12V STI Trigger 8 Electrical Hookup Keypad 10 Electrical Hookup STI Trigger Connections 11 Electrical Hookup Cima Link Operation optional 12 Electrical Hookup Cima Link Controller optional 13 Electrical Hookup Cima Link Infrared optional 15 Step 3 Installing the Screen Case Into the Ceiling 16 Operating the Screen 17 Screen Tension Adjustment 19 Owner s Manual ...

Страница 4: ...on which the screen isbeing mounted See instructions for the type of mount for recommendations 4 The Cima Above Ceiling s screen motor is pre wired at the factory No additional motor assembly is required Description Motor Wiring The Cima Above Ceiling product can be controlled through a number of remote control devices including keypads dry contact outputs and low voltage trigger outputs With the ...

Страница 5: ...6 in 7 3 4 in 6 1 2 in DETAIL A 10 in MOUNTING HOLES SELF FINISHING FLANGE VIEWING SIDE FINISHED CEILING PRODUCT DIMENSIONS 2015 Stewart Filmscreen Corporation Cima Above Ceiling ElectriScreen Owner s Manual 5 ...

Страница 6: ...B RJ25 CONNECTOR SCREEN MOUNTING BRACKET POWER CORD 3 DETAIL B LOW PROFILE MOUNTING BRACKET PRODUCT DIMENSIONS CONTINUED 2015 Stewart Filmscreen Corporation 6 ...

Страница 7: ...on is on the left side audience left LOW PROFILE MOUNTING BRACKET Figure 1 Low profile Mounting Bracket 2015 Stewart Filmscreen Corporation Cima Above Ceiling ElectriScreen Owner s Manual 7 POWER CORD The unit is usually suspended as shown in Figure 1 but it can be secured to the ceiling using bolts or other appropriate fasteners as well Follow this procedure to mount the case The Cima Above Ceili...

Страница 8: ...p 2 ELECTRICAL HOOK UP KEYPAD Press the Down button once and the Cima screen will automatically extend fully to its pre set limit and then will power itself off Press the Up button once and the Cima screen will automatically retract back into the case and power itself off If a custom position is desired simply press the Stop button at any time during the screen s deployment or retraction to set it...

Страница 9: ...ort these inputs to ground The voltage sensing input will trigger an up or down motor movement based on the voltage level A voltage level between 5vdc and 12vdc will drive the motor down a 0vdc will drive the motor up A signal changing from 0 to 12v will trigger the down a transition from 12v to 0v will trigger an up All inputs are protected from static discharge Figure 3 STI Controller internal C...

Страница 10: ...ither can be used as shown below LV1 and LV2 are the close contact connections these require a short to common to activate An external switch or relay should connect this to the common In the open circuit there is about 5Vdc present on the connection STI is the voltage sensing connection An external device should connect to this pin and common 10 STEP 3 ELECTRICAL HOOK UP FOR 12V STI TRIGGER CONTI...

Страница 11: ...onfiguration 2 12 V Trigger to Screen Configuration 1 Keypad to Screen Configuration 3 12 V Trigger Keypad to Screen 2015 Stewart Filmscreen Corporation Cima Above Ceiling ElectriScreen Owner s Manual 11 ...

Страница 12: ...nctions In addition interface adapters are available which enable IMC motor controllers to be connected to nearly any type of system without third party drivers 12 VPAD virtual keypad PC application Any third party Serial COMM Utilities Lighting Shading Panels from Lutron and Vantage Automation systems from AMX Crestron Control 4 Elan Home Systems and others Optional IR sensor can be connected for...

Страница 13: ...ial adapter that plugs anywhere onto the CS Bus network line up 4 000 feet from the Cima screen CIMA LINK CONTROLLER PACKAGES OVERVIEW Figure 5 shows example applications of the Cima Link Controller Accessories not included for which the Cima Above Ceiling ElectricScreen can be integrated with infrared remote additional Cima screens and 3rd party applications Figure 5 Cima Link Controller Package ...

Страница 14: ...h pair wires The IMC 100C Controllers J3 connector is designed to accept up to two 2 dry contact closures as well as one voltage triggering input such as those available with screen trigger or external 12V contact closures Controlling Multiple Cima products 14 The Cima Link Controller is a state of the art bi directional communication AC motor controller designed to control up to With the Cima Lin...

Страница 15: ... 2015 Stewart Filmscreen Corporation Infrared Receiver Cima Above Ceiling ElectriScreen Owner s Manual 15 IR Remote Keypad to Screen Cima Link Infrared Package ...

Страница 16: ...een Perform the following actions to avoid damage Wear clean gloves throughout the installation process to prevent damage to the screen housing or screen material 3 Fasten the Cima screen housing mounting brackets to the threaded rod or beams above the ceiling When installing the Cima housing assembly make sure that the screen batten never contacts or strikes any objects as damage may occur as a r...

Страница 17: ...ly follow these instructions Caution Do not operate the motor when any of the following occurs The unit emits any smoke heat abnormal noise or unusual odor The unit is damaged in some way such as damage from a water leak If any of these situations occurs call a qualified service person Improper adjustment of the limit switches can cause irreparable damage to the screen itself resulting in voiding ...

Страница 18: ...make approximately a 3 4 2 cm change in the screen s stop position 18 ADJUSTING THE SCREEN EXTENSION CONTINUED To decrease the screen extension 1 Lower the screen until it is extended about halfway down 2 Remove the dust cover to locate the white extension down limit switch on the left side of the screen tube audience left Use a small electrician s style screwdriver or a 5 32 4 cm hex wrench to tu...

Страница 19: ...rimarily in the lower section of the image area In many instances the screen s factory deployment setting has been reduced at the site and therefore this batten adjustment is necessary The objective is to thread the screw into the ferrule just enough to get a very low amount of side line tension approximately 3 to 4 turns The side lines will now have less tension which is desirable The result is t...

Страница 20: ...k of the screen with a clean damp cloth For tougher spots use a solution of mild detergent and water Rub lightly using a sponge Blot with a damp sponge to absorb excess water Residual water marks will evaporate within a few minutes Let the screen air dry completely before retracting Do not use any other cleaning materials on the screen Contact the factory if you have questions about removing diffi...

Страница 21: ...d by voltage drop bad connections or a defective switch Have an electrician or qualified service person check all hook ups including all outboard wiring Unit hums in up mode Screen has already retracted The screen batten is retracting too far into the case Failure to correct can damage motor and screen Do not use the unit until this problem is resolved Have a qualified service person adjust the ye...

Страница 22: ...tive and takes time to dissipate If motor use is initiated before it has cooled completely the motor will shut down again when it reaches maximum temperature Dirt fingerprints marks etc on screen surface Indentations appear on screen surface Debris or particles adhering to screen due to static cling Check back of screen gently brush debris away by hand STI IMC fails to operate motor Improper handl...

Страница 23: ...n freight expenses to and from Stewart are payable by the purchaser Stewart is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives will Stewart be liable for sums in excess of the purchase price of th...

Страница 24: ...1 800 762 4999 Fax 310 326 6870 15416 www stewartfilmscreen com ...