![CIGWELD WELDSKILL 200HF Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/cigweld/weldskill-200hf/weldskill-200hf_operating-manual_2607049054.webp)
OPERATING MANUAL
200HF
SERVICE 7-4 Manual 0-5406
Power Source Problems Cont'd
Description
Possible Cause
Remedy
9
TIG electrode melts when arc
is struck
A
TIG torch is connected
to the (+) terminal
A
Connect the TIG torch to the (-)
terminal
B
Incorrect Shielding Gas
is being used.
B
Ensure that Welding Grade Argon
is being used.
C
Inadequate shielding
gas flow or shielding
gas not turned on.
C
Turn on shielding gas and set
shielding gas flow rate for the
welding job. Refer to Table 5-5 on
Page 5-7.
D
Incorrect Tungsten
D
Check Tungsten type and size and
change if necessary.
10 Arc flutters during TIG
welding
Tungsten electrode
is too large for the
welding current
Select the correct size of tungsten
electrode refer to Table 5-1 Cigweld
Tungsten Electrode Selection Chart.
Table 7-1