![CIGWELD WeldSkill 200AC/DC Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/cigweld/weldskill-200ac-dc/weldskill-200ac-dc_service-manual_2607048032.webp)
WELDSKILL 200AC/DC INVERTER
OPERATION
Operation 4-10
Manual 0-5206
Wave Balance
This parameter operates in AC
TIG mode and is used to set the
penetration to cleaning action
ratio for the AC weld current.
Generally WAVE BALANCE is set
to 50% for AC STICK welding.
The WAVE BALANCE control
changes the ratio of penetration
to cleaning action of the AC TIG
welding arc. Maximum weld
penetration is achieved when
the WAVE BALANCE control is
set to 10%. Maximum cleaning
of heavily oxidised aluminium or
magnesium alloys is achieved
when the WAVE BALANCE control
is set to 65%.
Volts
VOLTS
SECONDS
PERCENT (%)
FREQ (Hz)
10 to 65%
Table 4-2
WAVE BALANCE is used for aluminium welding in AC HF TIG or AC LIFT TIG mode
It is used to set the ratio of penetration to cleaning action for the AC TIG welding arc.
Maximum weld penetration is achieved when the WAVE BALANCE is set to 10%. Maximum cleaning of heavily
oxidised aluminium or magnesium alloys is achieved when the WAVE BALANCE is set to 65%.
Maximum Penetration and
reduced cleaning
Balanced with 50% penetration
and 50% cleaning
Maximum Cleaning and
reduced penetration
10%
50%
65%
90%
50%
35%
(+)
(+)
(+)
(-)
(-)
(-)
Wave Balance = 50%
Wave Balance = 10%
Wave Balance = 65%
A-11223
Table 4-3: AC TIG Wave Balance
4.04 Short Circuit Protection While Welding
To prolong the useful life of a TIG tungsten electrode, the Weldskill 200 AC/DC incorporates special circuitry.
In DC LIFT TIG mode, if the tungsten electrode touches the work the welding current is reduced to 20 Amps.
In DC HF TIG mode, if the tungsten electrode touches the work the welding current is reduced to 0 Amps
within 1 second.
In STICK mode, if the electrode touches the work for more than two seconds the welding current is reduced
to 0 Amps.
65
Содержание WeldSkill 200AC/DC
Страница 6: ...WARRANTY TERMS INSIDE REAR COVER GLOBAL CUSTOMER SERVICE CONTACT INFORMATION REAR COVER ...
Страница 16: ...WELDSKILL 200AC DC INVERTER INTRODUCTION Introduction 2 2 Manual 0 5206 Notes ...
Страница 40: ...Theory of Operation 5 2 Manual 0 5206 WELDSKILL 200AC DC INVERTER THEORY OF OPERATION Notes ...
Страница 58: ...Troubleshooting 6 18 Manual 0 5206 WELDSKILL 200AC DC INVERTER TROUBLESHOOTING Notes ...
Страница 70: ...WELDSKILL 200AC DC INVERTER DISASSEMBLY PROCEDURE Disassembly Procedure 7 12 Manual 0 5206 Notes ...
Страница 82: ......
Страница 84: ......