TROUBLE SHOOTING
TRANSMIG 250i
Manual 0-5188
6-11
TROUBLE SHOOTING
NOTE
If the new calibration values pass internal
checks and are accepted, the operator will
briefly observe the flashing decimal points
pattern in the left hand display when pressing
the knob to save the data. If the new values
do NOT pass internal checks, the original/
previous data is retained and the flashing
decimal point is not shown.
14. Turn unit off
15. Disconnect the input power to the welding power
supply.
16. Remove (4) front panel screws
Art # A-10406
Figure 6-7: Screw Location
17. Locate the SERVICE Dip switch on the back of
the control board and set the number "1" dip
switch to the "OFF" position.
18. Reinstall the control panel with all (4) screws.
19. Re-connect the input power to the welding
power supply. Calibration is complete.
6.08 Wire Speed Calibration
Follow the previous steps in Sub Section 6.13 for setting
the Dip Switch for Calibration.
WARNING
DO NOT TOUCH the electrode wire while it is
being fed through the system. The electrode
wire will be at welding voltage potential.
Required Equipment/Tools:
• Appropriate personal protective gear: gloves,
safety glasses, etc.
• Tape measure
• Spool of desired filler metal
• MIG Gun
• T15 (Torx) driver
NOTE
To perform the wire feed speed calibration
procedure the end of the MIG wire needs to
be trimmed back to the contact tip of the
MIG Gun before and after feeding wire out
for measurement.
1. Enter Advanced Features Mode by pressing &
releasing Advanced Features Button.
2. Using the left knob, scroll through the menu list
to find and select “WFS CAL PROC”
.
Left Knob
3. Press and release the left knob to enter the Wire
Feed Speed Calibration Procedure. At this point,
the left display will show “SET / SPD1”, (Low
speed value) and the right display will show
the Factory set low speed wire feed calibration
value.
Left Knob
NOTE
The power supply requires two values to
properly calibrate wire feed speed. A low
feed speed value and a high feed speed
value. Default speeds span the most typical
jobs. You may choose alternates that better
represent your work. The closer an upper or
lower speed is to an actual procedure, the
better the accuracy.
Содержание 250i Transmig
Страница 56: ...TRANSMIG 250i INSTALLATION SETUP INSTALLATION SETUP 3 38 Manual 0 5188 Notes...
Страница 118: ...TRANSMIG 250i REPLACEMENT PARTS REPLACEMENT PARTS 8 4 Manual 0 5188 This Page Intentionally Blank...
Страница 120: ...TRANSMIG 250i APPENDIX APPENDIX A 2 Manual 0 5188 APPENDIX 2 TRANSMIG 250i CIRCUIT DIAGRAM Art A11458...
Страница 121: ...APPENDIX TRANSMIG 250i Manual 0 5188 A 3 APPENDIX Art A11458...
Страница 122: ...TRANSMIG 250i APPENDIX APPENDIX A 4 Manual 0 5188 Notes...
Страница 123: ...This page intentionally blank...
Страница 127: ......