Installation
2-37
3916 Service Delivery Switch
Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright
©
2013-2015 Ciena
®
Corporation
July 2015
Procedure 2-15
To Install a Pluggable Optic
The faceplate of the 3916 has 6 connections which use 100/1000 Mbps
Ethernet pluggable SFP optics.
shows the location of these different ports on the faceplate of the
3916.
Figure 2-12
Front view of the 3916 (3916 AC Standard system shown)
The following procedure explains how to install an SFP.
Step
Action
1
Hold the optic module by the sides and position it so that the label is facing
up and the 20-pin connector card (rear of the optic) is facing the empty optic
slot.
Note:
If installed upside down, the SFP will only insert halfway into the slot.
Remove the SFP, turn it over, and reinstall. Do not forcibly insert an SFP.
2
Gently insert the pluggable module into the available slot until it seats
completely. Take care not to crush the side clips, if present.
Note:
Certain types of SFP transceivers have small springs/clips on each
side, near the front (connector) end. These springs may catch on the SFP
cage during insertion, and prevent the full insertion of the optic. Take extra
care when installing these types of optics. If any resistance is encountered do
not force the optic into the slot. Bent springs may be carefully reformed with
needle nose pliers.
3
Gently pull on the SFP to make sure that it has seated properly.