Doppler Effect Microwave Detector “MWDT” 

 

1. General  information 

MWDT is an electronic microwave detector which can be 
combined with Darwin infrared barrier, whether indoors or 
outdoors. The wide radiation angle assure complete 
coverage of Darwin protected zone, in this way is possible 
to create a double technology protection. 
 

2. Wiring 

MWDT is sealed and is not possible to open it without 
damage; the pre connected cable must be wired to the 
Darwin terminal block so that the alarm contacts are in 
parallel, in this way the two detectors are working in “and” 
mode. To activate the LED function (which light on when a 
movement is detected) connect to the GND the white wire. If 
you keep this cable disconnected, the LED function will be 
disabled. 
 
 

+13,8V=
GND
Tamper
Tamper
Alarm
Alarm

 

Red 

13,8 V 

 

Gray 

GND 

Yellow 

Alarm contact 

Green 

Alarm contact 

White 

Signaling led 

Orange 

Not used 

Tab. 1 

 

 
 

  

 fig. 

(Darwin Rx terminal block) 

Содержание MWDT

Страница 1: ... MWDT Rivelatore a Microonde ad effetto Doppler Manuale d installazione Doppler Effect Microwave Detector Installation manual Edizione Edition 1 4 ...

Страница 2: ...ecnologia 2 Collegamento cavi 13 8V GND Tamper Tamper Alarm Alarm MWDT è sigillato e non è possibile aprirne il corpo senza danneggiarlo il cavo presaldato che esce dal sensore deve essere collegato sulla stessa morsettiera della barriera Darwin Rx in modo che i contatti d allarme siano in parallelo in questo modo i due rivelatori lavorano in AND Per attivare la funzionalità del led segnalazione d...

Страница 3: ...ferentemente secondo le esigenze del caso fig 2 4 Taratura MWDT non richiede alcuna taratura viene fornito in due versioni pretarate per una portata di 3m mod MWDT03 o 6m mod MWDT06 e non è possibile modificarne l impostazione 5 Avvertenze Evitare che oggetti creino zone cieche nell area protetta L installazione di più sensori nello stesso ambiente deve essere ponderata con cura è importante che l...

Страница 4: ...ta a Vn 13 mA Frequenza 24 162 GHz Massima potenza irradiata 40 mW E I R P Caratteristiche segnale emesso Pulsato duty cicle 10 Portata Fissa 3m o 6m Temperatura di funzionamento 25 C 55 C Resistenza contatto d allarme n c Max 40 ohm Ritenuta allarme 2 sec Dimensioni 40 x 56 x 20 mm Peso 30 g 80 gradi 32 gradi Irradiazione Verticale Irradiazione Orizzontale fig 3 ...

Страница 5: ...otection 2 Wiring MWDT is sealed and is not possible to open it without damage the pre connected cable must be wired to the Darwin terminal block so that the alarm contacts are in parallel in this way the two detectors are working in and mode To activate the LED function which light on when a movement is detected connect to the GND the white wire If you keep this cable disconnected the LED functio...

Страница 6: ...ting Minidoppler require no settings it is supplied in two versions presetted for 3m mod MWDT03 or 6m mod MWDT06 range and is not possible to modify this settings during installation 5 Warning Do not let any object create blind zones in the protected area The installation of 2 or more detectors in the same protected area mast be evaluated carefully it is important the emission of one sensor would ...

Страница 7: ...3 8 V Absorbed current 13 mA Frequency 24 162 GHz Irradiate max power 40 mW E I R P Radiated signal Pulsed duty cilce 10 Range Fixed 3m or 6m Operating temperature 25 C 55 C Normally closed alarm contact resistance Max 40 ohm Alarm hold 2 sec Dimension 40 x 56 x 20 mm Weight 30 g 80 gradi 32 gradi Lobe Vertical View Lobe Orizontal View fig 3 ...

Страница 8: ...gislazione nazionale vigente Il prodotto può essere riconsegnato al distributore installatore a fine vita in occasione di un nuovo acquisto This product is marked in compliance with the European Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE The correct disposal of the product will prevent potential negative consequences for the environment and the human health The symbol on t...