07/2020
Corona II
– LED Line Scan Illumination
PMA_CHR_CD40069_R05_Manual_Corona-II_XLC4
81
6.3.6.2
Signal “PWC” (pin 2) (only for XLC4-1)
Figure 6-8:
Typical Input Characteristic for Input PWC
PWC Max Voltage
Input Voltage PWC <= 6 V
PWC Max Current
Input Current PWC < 15 mA
PWC Low Current
Input Current PWC <= 0,7 mA
PWC High Current
Input Current PWC > 1,3 mA (Recommended >5 mA)
If PWC must be controlled with higher voltages, use a series resistor.
6.3.6.3
Signal “Fail” (pin 4)
Figure 6-9:
Output diagram of the open collector stage of FAIL
The driving Forward Current of the output stage is in the range 10 mA to 15 mA.
FAIL Max Voltage
Output Voltage FAIL <= 12 V
FAIL Max Current
Input Current FAIL <= 15 mA (Recommended: 5-10 mA)
The output transistor of FAIL is switched on if no error situation is detected.
Use a pull-up resistor at the receiving unit. Thus, an interrupt at the FAIL
signal line causes an error event (FAIL = H) at the receiver.