![chromasens allPIXA pro Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/chromasens/allpixa-pro/allpixa-pro_manual_2605692153.webp)
Chromasens CD40127_R02 allPIXA_pro_User Manual.docx
153
9.1.3 Line period time
Name
Name
Line period time
Function
Sets the value for line period in microseconds to the camera.
Unit
Float
Step:
0,001
Linear
Dependency
Only available if the Use line period check box is selected.
Notes
Value must be greater than that of Integration time.
Camera:
Value CST
Lower limit
4k
>19,68 µs
5K
>24,48 µs
6000
>29,14 µs
7.3k
>33,65 µs
Upper limit
All
9.25 ms
9.2 Gain settings
9.2.1 Analog coarse gain
This parameter describes the coarse gain parameter of the camera, which takes effect in step
(1) of analog image processing (section
Analog / digital image processing
Name
Name
Analog Coarse Gain
Function
Pre-amplification after CCD and before analog gaining.
Channels
Red, Green, Blue
Front; Rear
Unit
-3 dB;0 dB;+3 dB; +6 dB
Log.
Dependency
None
Notes
Use this parameter for a rough adjustment of gaining at the first step.
Camera:
Value CST:
Lower limit
all
-3 dB
0 dB
3 dB
Upper limit
All
6 dB
Line period
Line period
Line period
Int. time
Int. time
Int. time