Table C – E4 Housing Renewal Parts Identification

Table D – E2 Housing Renewal Parts Identification

TA -   S7 -   E F.

Litho in U.S.A.

2150 N. RULON WHITE BLVD., OGDEN, UT 84404

Phone: 1-800-368-2493         www.chromalox.com

TYPE LTFX RENEWAL PARTS IDENTIFICATION

Heater

Immersion

ANSI

Number

Tube

OCE

Replacement

Model

kW

Volts

Phase

Length (In.)

Flange Size

of Tubes

Diameter

Element No.

OCE Model No.

LTFX-125-004E4

4

480

3

60

4" - 150#

1

2"

#1

OCE-05040-2-483

LTFX-128-008E4

8

480

3

96

4" - 150#

1

2"

#2

OCE-06080-2-483

LTFX-1212-012E4

12

480

3

144

4" - 150#

1

2"

#3

OCE-12120-2-483

LTFX-2212-024E4

24

480

3

144

6" - 150#

2

2"

#3

OCE-12120-2-483

LTFX-3212-036E4

36

480

3

144

6" - 150#

3

2"

#3

OCE-12120-2-483

LTFX-2325-060E4

60

480

3

300

8" - 150#

2

3"

#4

OCE-25300-3-483

LTFX-3325-090E4

90

480

3

300

10" - 150#

3

3"

#4

OCE-25300-3-483

LTFX-4325-120E4

120

480

3

300

10" - 150#

4

3"

#4

OCE-25300-3-483

LTFX-6325-180E4

180

480

3

300

12" - 150#

6

3"

#4

OCE-25300-3-483

LTFX-8325-240E4

240

480

3

300

14" - 150#

8

3"

#4

OCE-25300-3-483

Heater

Immersion

ANSI

Number

Tube

OCE

Replacement

Model

kW

Volts

Phase

Length (In.)

Flange Size

of Tubes

Diameter

Element No.

OCE Model No.

LTFX-125-004E2

4

480

3

60

4" - 150#

1

2"

#1

OCE-05040-2-483

LTFX-128-008E2

8

480

3

96

4" - 150#

1

2"

#2

OCE-06080-2-483

LTFX-1212-012E2

12

480

3

144

4" - 150#

1

2"

#3

OCE-06080-2-483

LTFX-3210-024E2

24

480

3

120

8" - 150#

3

2"

#2

OCE-06080-2-483

LTFX-3215-036E2

36

480

3

180

8" - 150#

3

2"

#3

OCE-06080-2-483

LTFX-3225-060E2

60

480

3

300

8" - 150#

3

2"

#5

OCE-25200-2-4803

LTFX-4225-090E2

90

480

3

300

10" - 150#

4

2"

#6

OCE-25225-2-4803

LTFX-8215-120E2

120

480

3

180

12" - 150#

8

2"

#7

OCE-15150-2-4803

LTFX-9220-180E2

180

480

3

240

14" - 150#

9

2"

#5

OCE-25200-2-4803

LTFX-12225-240E2

240

480

3

300

14" - 150#

12

2"

#5

OCE-25200-2-4803

MAINTENANCE

ELECTRIC SHOCK HAZARD.  Disconnect all power
before installing or servicing heater.  Failure to do
so could result in personal injury or property dam-
age. Heater must be installed or serviced by a
qualified person in accordance with the National
Electrical Code, NFPA 70. 

1. 

Make certain both the terminals and the ceramic insulators are free
from contact with oil, liquid, or other foreign matter.
NOTE: Chromalox cannot be responsible for failures or damage
caused by contamination on the ceramic insulators. Make certain the
heaters are not exposed to contaminants.

2.

Check electrical connections at heater terminals and tighten if neces-
sary. This will help avoid hot terminals which may destroy wire insu-
lation or heater terminals

3.

Check overheat operation to assure heater protection.

Element Replacement - Moisture Resistant Housing Only
(E4 Option)
1.

To remove the OCE heating elements, first turn the circuit breaker to
the off position. 

2.

Next remove the housing lid, element wiring and the element mount-
ing screw. Now pull the element straight out of the heating tube.

NOTE:

OCE elements should only be bent in a vertical plane with

ground strap on the bottom.

3.

When removing the heating elements, make certain that the terminals

and the ceramic insulators do not contact oil or any other liquid foreign
matter. 

NOTE:

Chromalox cannot be responsible for failures or dam-

age caused by contamination on the ceramic insulators.

4. 

Installation is the reverse of the above.

Element Replacement - Hazardous Locations, Explosion Resistant
Housing Only (E2 option)
1.

To remove the OCE heating assembly, first turn the circuit breaker to
the off position. 

2.

Next remove the housing lid, element wiring, and 5/16” bolting around
the element flamepath module. If needed, (2) 1/4-20x2” bolts may be
used to break loose the module from the flange. Turn bolts evenly until
module is free. The flamepath module will be re-used, so disconnected
the heating element from the module pins. Now pull the element
assembly out of the heating tube. NOTE: OCE elements should only be
bent in a vertical plane with ground strap on the bottom.

3.

When removing the heating elements, make certain that the terminals
and the ceramic insulators do not contact oil or any other liquid foreign
matter. 

Note:

Chromalox cannot be responsible for failures or damage

caused by contamination on the ceramic insulators.

4. 

Inspect the element assembly flange and mating surface for any debris,

oils, or contamination. 

NOTE:

Surfaces must be in suitable condition

to ensure proper hazardous rating.  

5.

Connect the new element to the flamepath module and slide into tube.

Flamepath module bolting must be tightened to XXX ft. lbs. of torque.

6. 

Reattach element wiring. When reinstalling housing lid, be sure to prop-

erly align gasket, and tighten housing bolts to 40-50 in-lbs.

Limited Warranty:

Please refer to the Chromalox limited warranty applicable to this product at

http://www.chromalox.com/customer-service/policies/termsofsale.aspx.

Содержание PN403-1

Страница 1: ...8 51100 LTFX 6325 180E4 180 480 3 3 300 12 150 6 3 9 N A 4432 348 51100 LTFX 8325 240E4 240 480 3 4 300 14 150 8 3 9 N A 4432 348 51100 Specifications E4 Moisture Resistant Housing Immersion ANSI Flange Number Tube Watt Density Matching Control Panel Heater Model kW Volts Phase Circuits Length In Size of Tubes Diameter Outside PCN Model LTFX 125 004E2 4 480 3 1 60 4 150 1 2 10 LTFX 128 008E2 8 480...

Страница 2: ...oom must be provided for this purpose The removal length of the OCE heating element is 3 feet since the cen ter section may be bent on a 12 radius OCE elements should only be bent in a vertical plane with ground strap on the bottom B The neck on the tank s mating flange should be of adequate length to accommodate tank insulation and flange bolting 5 Tube supports internal to the tank should be pla...

Страница 3: ...quip ment is responsible for determining the proper classification of an area and for providing Chromalox with hazardous area specifica tions and requirements for proper equipment design NEC and IEC provide guidelines for evaluating and classifying hazardous locations An approved liquid level control or overtemperature control must be installed to deenergize the heater if the liquid level drops be...

Страница 4: ...sed to contaminants 2 Check electrical connections at heater terminals and tighten if neces sary This will help avoid hot terminals which may destroy wire insu lation or heater terminals 3 Check overheat operation to assure heater protection Element Replacement Moisture Resistant Housing Only E4 Option 1 To remove the OCE heating elements first turn the circuit breaker to the off position 2 Next r...

Отзывы: