RENEWAL PARTS IDENTIFICATION
4
2
3
Aluminum
Model
Volts
Watts
Element*
Reflector
Housing
U-RAD-2LT
120
UTU-2LT
U-RAD-2VLT
208
800
UTU-2VLT
234-013411-032
152-016961-001
U-RAD-2LT
240
UTU-2LT
U-RAD-2VLT
275
UTU-2VLT
U-RAD-3LT
120
UTU-3LT
U-RAD-3VLT
208
1100
UTU-3VLT
234-013411-033
152-016961-002
U-RAD-3LT
240
UTU-3LT
U-RAD-3VLT
275
UTU-3VLT
U-RAD-4VLT
208
UTU-4VLT
U-RAD-4LT
240
1800
UTU-4LT
234-013411-034
152-016961-003
U-RAD-4VLT
275
UTU-4VLT
U-RAD-4LT
480
UTU-4LT
U-RAD-5VLT
208
UTU-5VLT
U-RAD-5LT
240
2500
UTU-5LT
234-013411-035
152-016961-004
U-RAD-5VLT
275
UTU-5VLT
U-RAD-5LT
480
UTU-5LT
U-RAD-6VLT
208
UTU-6VLT
U-RAD-6LT
240
3000
UTU-6LT
234-013411-036
152-016961-005
U-RAD-6VLT
275
UTU-6VLT
U-RAD-6LT
480
UTU-6LT
U-RAD-7VLT
208
UTU-7VLT
U-RAD-7LT
240
3600
UTU-7LT
234-013411-037
152-016961-006
U-RAD-7VLT
275
UTU-7VLT
U-RAD-7LT
480
UTU-7LT
U-RAD-22LT
120
UTU-2LT (2)
U-RAD-22VLT
208
1600
UTU-2VLT (2)
234-013411-032 (2)
152-016963-001
U-RAD-22LT
240
UTU-2LT (2)
U-RAD-22VLT
275
UTU-2VLT (2)
U-RAD-32LT
120
UTU-3LT
234-013411-033
UTU-2LT
234-013411-032
U-RAD-32VLT
208
UTU-3VLT
234-013411-033
1900
UTU-2VLT
234-013411-032
152-016963-002
U-RAD-32LT
240
UTU-3LT
234-013411-033
UTU-2LT
234-013411-032
U-RAD-32VLT
275
UTU-3VLT
234-013411-033
UTU-2VLT
234-013411-032
5
6
2
13
14
15
4
3
7
8
10
11
9
1
Element assembly includes all parts shown except items
3
and
4
For element assembly part number, and prefix “R” to Element part
number 2 Ex: R UTU-6VLT, 208V, 3000W
Figure 8
MAINTENANCE
ELECTRIC SHOCK HAZARD. Disconnect all power
before installing or servicing heater. Failure to do
so could result in personal injury or property dam-
age. Heater must be installed or serviced by a
qualified person in accordance with the National
Electrical Code, NFPA 70.
To Remove Heating Element —
1.
Remove terminal box cover
6
.
2.
Disconnect heating element from electrical leads.
3.
Remove threaded fitting nuts
9
and washers
8
.
4.
Remove element support clips and secondary insulating bushings.
5.
Lift out element.
To Install Element —
Observe instructions for removing element and proceed in
reverse order. Be sure to replace secondary insulating bushings.
Care of Reflectors —
Reflectors should be cleaned periodically. A mild soap and
water solution or fine cleaning powder is best although more dras-
tic means may be required if reflectors are badly soiled by chemi-
cal or other deposits. The reflector is aluminum. DO NOT use
alkali cleaners since alkalies will dull reflector. Mild non-alkaline
cleaners, such as used for scouring kitchen sinks, may be used.
Reflectors are replaceable and may be purchased from Chromalox.