background image

(Supersedes PF421-5)

PF421-6

EH-HVT

161-048557-001

APRIL, 2003

4

and

Installation, Operation

RENEWAL PARTS IDENTIFICATION

Type EH and HVT Electric Utility Heater

Spe

cification

s

 – Tabl

e

 A

GENERAL

FIRE HAZARD. Since heaters are capable of devel-
oping high temperatures, extreme care should be
taken to:

A.

Locate on vertical wall with length of heater positioned horizon-
tally. HVT models must be installed with thermostat at right end;

B.

Avoid mounting into a wall recess since such mounting interferes
with free air circulation, increases heater temperatures, and pre-
vents proper thermostat operation on HVT models;

C.

Mount heaters with a minimum clearance of  24” above floor level
or from adjacent wall;

D.

Keep all combustible materials a minimum of 4” from front and
top of heater.

1.

Remove screw from each end and remove perforated cover.

2.

After feeding electrical wiring through opening in back of heater
(See WIRING section), mount back of heater to wall with four
screws (HVT models-5/16” diameter holes on 5” x 25-7/8”) (EH
models 9/32” diameter holes on 5x12-1/2” centers) through back
of heater. Leave one pair of end screws snug, but not tight, to avoid
expansion noise due to binding.

Ty

pe

 HVT*

NOTICE: Ca

re

f

u

lly 

re

mov

e

  h

e

at

er

  f

r

om ca

r

ton an

d

 ch

e

ck fo

r

s

hi

pp

ing 

d

amag

e

. Any 

d

amag

e

 claim

s

 

s

ho

u

l

d

  b

e

 

e

nt

ered

imm

ed

iat

e

ly with th

e

 ca

rr

i

er

.

Dim. “A”

Mo

de

l

Volt

S

Watt

S

(

In.

)

BTUH

EH-1221

120

250

14

5

/

8

853

EH-1221

240

250

14

5

/

8

853

EH-1251

120

500

14

5

/

8

1706

EH-1251

240

500

14

5

/

8

1706

HVT-1251*

120

500

28

5

/

8

1706

HVT-2411*

120

1000

28

5

/

8

3412

*HVT models are equipped with a 55°F to 110°F adjustable thermostat.

Ty

pe

 EH

Thermostat

(HVT Only)

A (HVT)

A (EH)

6

3

/

4

3

3

/

4

© 2010 Chromalox®, Inc.