background image

1

3

5

7

8

4

6

2

Safety Switch

Service Wires

Fan

GND

1

3

5

7

8

4

6

2

Safety Switch

Service Wires

Fan

GND

1

3

5

7

8

4

6

2

Safety Switch

Service Wires

Fan

GND

Factory Connection

208/240V

675/900W

May be field 

120V

450, 900, 

reconnected to

1350, 1800W

208/240V

1350/1800W

Electrical Inspection —

Remove grille, screen and frame by removing screws “A”.
Remove screws “C” at front of junction box. The junction box cover
can now be removed through the front opening, and field wiring can
be observed. When re-assembling, reverse the procedure above.

Cleaning —

WARNING:

Hazard of Severe Shock. Disconnect all

power to heater before servicing.

With Grille in Place :

Use vacuum cleaner hose to suck out lint and dirt around grille.
Reverse hose on vacuum to use as a blower to move dust out of enclo-
sure. Reverse hose back to suck out dirt at front area of heater.

With Grille Removed :

Remove two screws “B” at bottom front of heating element assembly.
Pull gently on assembly to remove it from the enclosure. Swing assem-

bly out. Vacuum inside of enclosure and around heating element
assembly. Reverse procedure above to re-assemble unit.

Note 1:

Care must be taken to prevent undue strain on all wiring or
heating element assembly, when removing and re-assembling
heating element assembly.

Note 2:

For field rewiring to 120V, all leads must be secured under
wire clamps.

Note 3:

Air and grille temperatures may discolor certain materials,
particularly those materials incorporating clear vinyl.
Materials should be checked prior to installation to determine
if discoloration or distotion would occur in the vicinity of
140˚F (60˚C).

2150 N. RULON WHITE BLVD., OGDEN, UT 84404

Phone: 1-800-368-2493         www.chromalox.com

MAINTENANCE

WARNING:

Hazard of Severe Shock. Disconnect all

power to heater before servicing or replacing heaters.

Normal maintenance requires only an occasional vacuuming using
standard vacuum attachments.

WARNING:

Do not block air flow in any way with

drapes, rugs or other objects.

REPLACEMENT PARTS

For replacement parts, please consult with the Product Service Center listed below.

22-3/8"

3-5/8"

3-1/2"

22"

9-1/2"

3"

Max

Knockouts

Service Cable

10" Min

Ceiling

Grille

Heater

Cabinet Door

Partition or

Added Support

3/4"
Min

Figure 3

Figure 2

Figure 1

Top Label

Heater Cover

Junction Box Cover

Screw “C”

Screw “A”

Trim Frame

Grille

Screw “B”

Heater Element

IMPORTANT: 

Retighten all leads with cable

clamp after reconnecting uninsulated ends
of unused leads with wire nuts.

Rating

Connect

450W  3.75A

7-8 (As Shown)

900W  7.5 A

7-8, 1-2

1350W  11.2A

7-8, 1-2, 3-4

1800W 15A

7-8, 1-2, 3-4, 5-6

208/240 Volt 675/900 Watts
(Factory Connection) 3.2A/3.7A

208/240 Volt 1350/1800 Watts
(Field Connection) 6.5A/7.5A

120V  (Field Connection) 

Figure 4

Limited Warranty:

Please refer to the Chromalox limited warranty applicable to this product at

http://www.chromalox.com/customer-service/policies/termsofsale.aspx.