Manual Operation
3-57
1.
In Config Setup page, press “
6
” and
ENTER
to enter into the FACTORY SETTING
option as Figure 3-99 shows.
FACTORY DEFAULT has two options: (1) NO and (2) YES.
When set to FACTORY DEFAULT = NO the instrument will retain the last configuration
saved by user. On the contrary, if it is set to FACTORY DEFAULT = YES all
configuration settings will return to the factory default.
In the meantime, the screen will display 5 types of messages DEVICE MODEL, SERIAL
NO., FIRMWARE VERSION, FPGA VERSION and MODULE VERSION.
DEVICE MODEL
: Display the model no.
62150H-600S
as Figure 3-99 shows.
SERIAL NO.
: Display the serial no.
22
as Figure 3-99 shows.
FIRMWARE
VERSION
: Display firmware version
01.11
and the released date Feb 1,
2010 as Figure 3-99 shows.
FPGA VERSION
:
Display the FPGA version no.
01.00,01.00
as Figure 3-99
shows.
MODULE VERSION
:
Display the module version no.
01.00,01.00,01.00
3-99 shows.
[ F A C T O R Y D E F A U L T ]
R E C A L L
D E F A U L T
= N O _
D E V I C E
M O D E L
: 6 2 1 5 0 H
–
6 0 0 S
S E R I A L N O : 2 2
F I R M W A R E V E R S I O N
: 0 1 . 1 1, F e b 1 2 0 1 0
F P G A V E R S I O N
: 0 1 . 0 0 , 0 1 . 0 0
M O D U L E V E R S I O N : 0 1 . 0 0 , 0 1 . 0 0 , 0 1 . 0 0
Figure 3-99
3.3.7
CALIBRATION
Chroma 62000H Series DC Power Supplies with Solar Array Simulation provide (1)~(5)
calibration functions while A620028/A620027 provides the previous (1)(2)(3) calibration
functions and the 62020H-150S model provide (1)~(7) calibration functions:
(1) VOLTAGE: the actual voltage output (CV mode) and its measurement accuracy.
(2) CURRENT: the measurement accuracy of current.
(3) CURRENT: the actual current out (CC mode).
(4) APG VOLTAGE: the actual voltage output and its accuracy of analog V Monitor under
analog voltage control mode.
(5) APG CURRENT: the actual current output and its accuracy of analog I Monitor under
analog current control mode.
(6) IV VOLTAGE: the actual voltage setting (CV mode) and measurement accuracy in SAS
mode.
(7) IV CURRENT: the current measurement accuracy in SAS mode.
Follow the procedure below to enter into calibration mode: