Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
3-20
When Foldback protection occurs the main page will prompt a protect message as
Figure 3-29 shows.
Figure 3-29
Be aware that if delay time sets to
t
seconds, it means the Foldback that set to CV TO
CC or CC TO CV won’t be activated unless it sustains
t
seconds when a mode change
is detected. If the change time of mode is less than
t
seconds it will return to its original
state and Foldback protection will not occur as Figure 3-30 shows.
DELAY TIME
C V MODE
CC
MODE
Time
FOLDBACK
PROTECTION
DC SOURCE OPERATION MODE
Figure 3-30
Assuming the Foldback is set to CV TO CC, the solid line in Figure 3-30 will create
Foldback protection while the dot line will not.
3.2.3.5
Meas. Setting
1.
Tap Meas. Setting to enter into Measurement Setup as Figure 3-31 shows.
2.
There are Average Time and Average Method for setting.
Содержание 62000D Series
Страница 1: ......
Страница 2: ...Get more information by downloading Chroma ATE Solutions APP ...
Страница 8: ...vi ...
Страница 9: ...vii ...
Страница 10: ...viii ...
Страница 14: ......
Страница 18: ......
Страница 35: ...Overview 1 17 Figure 1 6 Dimension of 62000D 600 1200 1800 Models ...
Страница 36: ......
Страница 52: ......
Страница 54: ...Programmable Bidirectional DC Power Supply 62000D Series Operating and Programming Manual 3 2 Figure 3 2 ...
Страница 63: ...Manual Operation 3 11 Figure 3 13 Figure 3 14 ...
Страница 109: ...Manual Operation 3 57 _EXT ON SIGNAL EXT ON DISABLE EXT ON ENABLE Output Output Figure 3 85 ...
Страница 110: ......
Страница 117: ...Program Sequence 4 7 Figure 4 8 Figure 4 9 ...