MAINTENANCE AND INSPECTION

 

 

All inspection and maintenance procedures should be carried out by a competent and authorised person. 
 
Should any faults be detected, the machine should not be used and a thorough examination should be 
carried out. 

 
The Hyspan Pistol Grip tool should be stored in a clean dry place. 
 
Please refer to the following for the Maintenance Schedule information. 
 
 

Daily/Before Use 

 

Section / 
Parts 

Inspection & Maintenance Procedure 

ALL 

Visual inspection on all parts 

ALL 

Ensure the oil within the system is clean and of suitable quality (Hydraulic 
mineral oil, none synthetic, Grade 32 or equivalent) 

 
 
 
 

Every 12 Months 

 
Section / 
Parts 

Inspection & Maintenance Procedure 

All 

Return back to W. Christie for full service, lubrication of moving parts and 
calibration 

 
 
 
 
 

WARRANTY  

 

This equipment has a 12 month warranty. 
 
This warranty excludes wear parts such as square drive and bearings. 
 
The warranty does not include misuse. 
 
For any further information please contact W. Christie (Industrial) LTD 
 
When returning tooling for examination, always ensure the reaction, Impact Socket and Power Pack are 
returned for inspection. 
 
 

Содержание HYSPAN

Страница 1: ...IE INDUSTRIAL LTD CHRISTIE HOUSE MEADOWBANK ROAD ROTHERHAM SOUTH YORKSHIRE S61 2NF UK T 44 0 1709 550088 F 44 0 1709 550030 E INFO WCHRISTIE COM W WWW WCHRISTIE COM Ref WCOI 101 Date July 2017 Issue 1...

Страница 2: ...ered by Manual Noise Vibration Levels 4 Parts Layout Assembly 5 Typical Connection Layout Torque Reaction 6 Safe Reaction Zone 7 Setting Torque and Operating Torque Tightening Setting Torque and Opera...

Страница 3: ...upply or via a Christie supplied power pack The direction is changed using the direction selector The unit is operated from a soft start trigger The Hyspan multiplier must always be operated with the...

Страница 4: ...are not run across walkways ladders roadways and doorways etc and that people likely to pass through the working area are aware of the danger To prevent entanglement with moving parts operators must n...

Страница 5: ...Extension Offset Gearbox Hydraulic Power Pack Units Impact Quality Sockets Torque Checking System Run Down Fixture MODELS COVERED BY MANUAL Model Weight Kg Speed rpm Torque Range Nm Square Drive HY10...

Страница 6: ...ing operation Connect the hoses to the hydraulic couplings on the Hyspan ensuring the fittings are connected correctly Refer to Typical Connection Layout on next page Connect the hoses to the power pa...

Страница 7: ...d to move the nut may be high enough to keep the reaction locked in one position This can cause the reaction plate to bend or cause gearbox failure To prevent failure re position the reaction plate af...

Страница 8: ...mage to the wrench Do not react on the reaction arm vertical crank Extreme forces are created which may cause damage to the wrench If the application does not allow the use of a standard reaction arm...

Страница 9: ...fastener is tight 7 Release the trigger 8 Remove the Hyspan tool from the fastener Note It may be necessary to set the tool to reverse and blip the trigger to enable it to be removed SETTING TORQUE A...

Страница 10: ...inspection on all parts ALL Ensure the oil within the system is clean and of suitable quality Hydraulic mineral oil none synthetic Grade 32 or equivalent Every 12 Months Section Parts Inspection Maint...

Страница 11: ...ned and manufactured in accordance with the following transposed harmonised European Standard BS EN ISO 12100 2 2003 Safety of Machinery Technical Principles 2006 42 EC Machinery Directive EN ISO 1210...

Страница 12: ...10...

Отзывы: