3
OPERATING INSTRUCTIONS
IMPORTANT: DO NOT OPERATE THIS TOOLING BEFORE THE OPERATING AND
SAFETY INSTRUCTIONS ARE READ AND UNDERSTOOD.
IF BREAKDOWN, MALFUNCTION OR DAMAGE OCCURS DO NOT
ATTEMP TO REPAIR, CONTACT W. CHRISTIE (INDUSTRIAL) LTD
IMMEDIATELY.
Before using the power pack electric unit ensure:-
1.
The operating and safety instructions are read and understood.
2.
The relief valve, located on the side of the unit is fully unwound (anti-clockwise)
3.
Tank is filled with oil (Tellus 32 or equivalent).
4.
Electric power supply is correct (110V or 240V).
5.
Couplings are clean and fully engaged.
6.
Connect hoses to the hydraulic tooling to be operated (see relevant operating instructions).
7.
Start the pump running by pressing the ‘on’ button on the back of the control panel.
8.
Depress the white button on the hand pendant.
9.
Slowly rotate the relief valve, cylinder will extend.
Note:
If cylinder does not extend, depress the black pendant button. Hydraulic pressure will register on
the gauge
10.
Adjust the hydraulic pressure to the required setting using the relief valve on the outside of the
unit.
11.
With pressure set, the power pack is now ready for use.
Note:
This is a double acting pump unit, depressing the pendant control buttons will extend or retract a
cylinder. Which button extends and which button retracts is dependant on hose orientation.