Lamp Replacement Instructions
013-100357-02 (Rev. 1)
1 of 5 Pages
Introduction
Use the following instructions when replacing the lamp on the projector model listed in
Table 1, below. The lamp is located at the front of the projector and can be accessed by
removing the front cover. Use only a Christie approved
Lamp Kit
for the specific projector
model.
Projector Model
Model Number
Required Lamp Kit
Christie DS
+
26 115-003101-01
003-120181-01
Warnings
Lamp replacement MUST be performed by a qualified service technician.
Cool the lamp completely (approximately 60 minutes) and handle by the housing
only.
Install the correct wattage lamp, supplied by Christie (Refer to Table 1. Projector
Models) and read the Lamp Replacement Procedure in its entirety before proceeding.
Do not touch the glass surface of the lamp. Fingerprints left on the surface can lead
to an intense accumulation of heat known as a “hotspot”, which could potentially
cause the lamp to shatter. It is recommended to wear clean, lint-free gloves and a
face shield when working with the lamp.
In the unlikely event that the bulb ruptures, small glass fragments may come loose.
The lamp module is designed to contain the glass fragments; however, it is advised
that extreme caution is exercised when removing the lamp module.
Table 1. Projector Models