2 of 4
DHD700/DHD800 Lamp/Filter Replacement Instruction Sheet
020-000207-02 Rev. 1 (10-2010)
Always power down and disconnect/disengage all power sources to the
projector before servicing or cleaning.
Allow the projector to cool for at least 45 minutes before the lamp cover is
opened. The inside of the projector can become very hot and may cause injury.
Do Not operate the projector while any of the lamps are removed. This may
result in malfunctions, fire hazard, or other possible accidents.
NOTICES: 1)
For continued safety, replace with a lamp assembly of the same type.
2)
Do not drop
the lamp assembly or touch a glass bulb! The glass can shatter and may cause injury.
Use the Lamp Status Display to verify which lamp needs to be
replaced.
1. Loosen the lamp cover screw (Figure 1-Top) and lift the
cover.
2. Loosen the 2 screws (Figure 1-Bottom) that attach the
lamp unit to the projector.
3. Use the handles to remove the lamp unit from the
projector (Figure 1-Bottom).
4. Set the new lamp unit into place and tighten the 2 screws
that attach it to the projector.
5. Slide the lamp cover back into place, and tighten the lamp
cover screw.
Figure 2 Lamp Replacement