Parameters
•
Access level: Operator
•
Power level (minimum): Power Up
Commands
Command
Description
Values
LVO?
Returns the current motor position along the
vertical axis and direction. (Read-only)
—
LVO <position> <1 | -1>
Moves the lens mount to a specified vertical
position with a specified direction.
position = Numeric value
-1 = Negative approach
1 = Positive approach
LVO+MOVR <step>
Moves the motor a given number of steps based
on the current location.
step = Numeric value
LVO+STOP
Stops the motor.
—
LVO+STRT <1 | -1>
Starts the motor moving in a specified direction.
-1 = Negative approach
1 = Positive approach
Examples
Return current motor position along the vertical axis and direction:
(LVO?)
Move lens to position 500 along the vertical axis with a positive approach:
(LVO 500 1)
Move lens to position 500 along the vertical axis with a negative approach:
(LVO 500 -1)
Move the motor 100 steps in a negative direction:
(LVO+MOVR -100)
Move the motor 200 steps in a positive direction:
(LVO+MOVR 200)
Stop the motor:
(LVO+STOP)
Start the motor moving in a positive direction:
(LVO+STRT 1)
C
™
serial commands
C Technical Reference–Serial Commands
20
020-103075-05 Rev. 1 (09-2022)