background image

LX380/LX450 Lamp/Filter Replacement Instruction Sheet

3 of 4

020-000107-01 Rev. 1 (10/08)

6. Reconnect power cord and turn the projector ON to reset the 

lamp time using the LAMP TIME function in the OPTION 
menu as follows:
a. Press the MENU button to display a menu. 

b. Use the 

 buttons to move the red framed pointer to 

the Setting Menu icon.

c. Use the 

 buttons to move the red-framed pointer to 

Lamp counter.

d. Press the SELECT button to display a dialog box show-

ing the Reset option.

e. Select Reset and to display “Lamp replacement counter 

Reset?” and select Yes.

f. A second confirmation dialog box appears; select Yes. 

NOTICE: 

DO NOT reset lamp counter unless the lamp has been 

replaced with a new lamp. 

FILTER REPLACEMENT

 

Always disconnect all power sources to the projector before servicing 

 

When replacing a filter, wait at least 45 minutes for the lamp to cool sufficiently. 

Handling the lamp while hot can cause burns, as well as damaging the lamp. Shards of glass may damage 
internal projector components or cause injury during handling.

NOTICES: 1) 

Use only the specified air filter. 

2) 

Do not use the projector with the air filter and/or the filter 

cover removed. It could result in a fire and/or malfunction to the projector.

 3) 

The air filter should be cleaned 

periodically. If the air filter becomes clogged by dust or similar, internal temperatures may rise and could 
cause a heat build-up and/or malfunction to the projector.

NOTES: 1) 

Replace the air filter when it is damaged or too soiled, and also when you replace the lamp. 

2)

 

Reset the filter time only when you have cleaned or replaced the air filter, for a suitable indication about the air 
filter. 

3)

 The projector may display the message “CHECK THE AIR FLOW” or turn itself off, to prevent the 

internal heat level from rising too high.

The filter prevents dust from accumulating on the optical elements inside the projector. Should the filter 
become clogged with dust particles, the effectiveness of the cooling fans will be reduced and may result in 
internal heat buildup which will adversely affect the life of the projector. 

NOTE:  

When the projector is suspended from the ceiling, use a vacuum cleaner to remove dust that has 

accumulated on and around the filter cover to avoid dust from entering the compartment when the filter cover 
is removed. 