background image

 

E461201 

T

T

T

o

o

o

u

u

u

c

c

c

h

h

h

-

-

-

P

P

P

a

a

a

n

n

n

e

e

e

l

l

l

 

 

 

1. 

Pointers 

 

1.1. 

Used symbols 

 

Symbols 

The following symbols are used in this instruction manual: 

 

DANGER! 

Denotes a direct threat of danger. Not observing this pointer may be life 
threatening or lead to serious injuries. 

 

CAUTION!

 

Denotes a possibly dangerous situation. Not observing this pointer can 
cause minor injuries or lead to material damages. 

 

INFORMATION! 

Denotes application pointers and other useful information. 

 

 

 
 

1.2. 

General pointers 

 

 

INFORMATION! 

This device was manufactured according to DIN EN ISO 9001 and left the 
factory in a perfect state. 
In order to maintain this state and to assure the safe operation, the user 
must consider the pointers and warning remarks, which are contained in 
this instruction manual. 

 
 
 

1.3. 

Safety pointers 

 

 

DANGER! 

In the case of damage of the box, the line or any other part of the device, 
disconnect it immediately from the supply voltage and shut it down. 

 

Disconnect every connection line before opening the device. 

 

 

 

 

 

 

Содержание Touch-it XPC

Страница 1: ...ied or distributed by means of electronic systems without previous written permission by Christ Elektronik GmbH The translation into another language also requires a written permission This documentation may be exclusively entrusted to the owner of the installa tion or to the employees of Christ Elektronik GmbH Technical changes Christ Elektronik GmbH reserves the right to change specifications ex...

Страница 2: ...pplication 8 5 Software 9 5 1 System Test and Initialization 9 5 2 System Configuration Verification 9 5 3 Award BIOS Setup 9 5 3 1 Changing Display Resolution 10 5 3 2 Changing Boot Priority 10 6 Touch Panel Driver 11 7 Interfaces 13 7 1 USB connection 13 7 2 Ethernet LAN 14 7 3 COM1 EIA 232 interface 14 7 4 VGA 14 8 Maintenance and servicing 15 8 1 Maintenance plan 15 8 2 Repairs 15 8 3 Cleaning...

Страница 3: ... damages INFORMATION Denotes application pointers and other useful information 1 2 General pointers INFORMATION This device was manufactured according to DIN EN ISO 9001 and left the factory in a perfect state In order to maintain this state and to assure the safe operation the user must consider the pointers and warning remarks which are contained in this instruction manual 1 3 Safety pointers DA...

Страница 4: ...r purposes or incorrectly operated Christ Elektronik GmbH will not hold damages liable Do not operate the touch sensitive surface of the screen with any abra sive or sharp edged objects Do not clean it with detergents containing solvent or acid Protect the Touch Panel against caustic chemicals and long solar radia tion INFORMATION Please check immediately Is the device damaged or is any equipment ...

Страница 5: ... clamp Wall Mounting in the wall Open Frame for dashboard 3 Display Screen size Native resolution 7 17 8 cm 800 x 480 10 4 26 4 cm 800 x 600 15 0 38 1 cm 1024 x 768 Technology Colours TFT 262 000 4 Backlight 1 CCFL switched 2 CCFL controlled 3 LED 5 Processor Type Frequency Intel Atom N270 1 6 GHz 6 Memory RAM 2 GB DDRII 7 Storage Compact Flash 8 GB 133x Hard Disk Drive 120 GB 2 5 SATA 8 Operation...

Страница 6: ...owing variants are available 3 1 VESA housing Picture 1 VESA mounting mounting variants front view desk stand surface mounting individual holder system 3 2 Switchgear cabinet housing Picture 2 switchgear cabinet housing mounting front view with fan fanless fasting clamp ...

Страница 7: ... o o u u u c c c h h h P P P a a a n n n e e e l l l 3 3 In wall housing Picture 3 wall mounting housing front view built in housing in the wall 3 4 Open frame Picture 4 open frame with front USB front view reverse view ...

Страница 8: ...is included in the delivery 4 1 2 4 1 2 4 1 2 4 1 2 Fasting Clamp for Switchgear Cabinet Housing Fasting Clamp for Switchgear Cabinet Housing Fasting Clamp for Switchgear Cabinet Housing Fasting Clamp for Switchgear Cabinet Housing Picture 6 fasting clamp Before you begin installing the Touch Panel into switchgear cabinet please make sure that the 10 clamps with setscrews have been shipped 4 2 Wir...

Страница 9: ...e application Picture 9 connection supply voltage VESA housing Pin 1 24 VDC nominal Pin 2 PE Pin 3 GND Mating with power supply plugs Hirose connectors RP34L 5PA 3SC or RP34L 5LP 3SC 1 2 3 Picture 10 connection supply voltage for all housing types but VESA Pin 1 GND Pin 2 PE Pin 3 24 VDC nominal Mating with power supply plugs phoenix connector MC 1 5 3 ST 3 5 BK USB COM1 EIA 232 Ethernet VGA ...

Страница 10: ...mation in memory There are three situations in which you will need to change the CMOS settings 1 You are starting your system for the first time 2 You have changed the hardware attached to your system 3 The CMOS memory has lost power and the configuration information has been erased The XPC Device CMOS memory has an integral lithium battery backup for data retention 5 3 Award BIOS Setup Awards BIO...

Страница 11: ...Once in the Setup mode choose the Advanced Chipset Features Menu and set the Internal LVDS as follows 7 0 Display 800x480 10 4 Display 800x600 15 0 Display 1024x768 Save this configuration by pressing the F10 and afterwards Y 5 3 2 5 3 2 5 3 2 5 3 2 Changing Boot Priority Changing Boot Priority Changing Boot Priority Changing Boot Priority In order to boot from a USB Drive the following settings m...

Страница 12: ...11 E461201 6 Touch Panel Driver 1 Click on Start All Programs Pen Mount Universal Driver Pen Mount Control Panel 2 Click on Pen Mount 6000 USB ...

Страница 13: ...activates the calibration screen to carry out calibration of the Touch Panel Briefly touch the center of the red square splayed on the screen in order as they appear Once calibration is carried out the calibrated value is saved Since the calibrated value is read from the setting file at the time of the next start up there is no need to carry out cali bration again ...

Страница 14: ...r 4 3 7 1 USB connection The Touch it XPC offers two USB ports The USB connections are pro vided for the connection of storage media as well as peripheral equip ment USB Mouse or Keyboard 4 3 2 1 Picture 12 USB Port 1 2 Connector Port1 Port2 pin 1 5V pin 1 5V pin 2 Data0 pin 2 Data1 pin 3 Data0 pin 3 Data1 pin 4 GND pin 4 GND Supply voltage Switch ON OFF USB COM1 EIA 232 Ethernet VGA ...

Страница 15: ... 5 D3 pin 2 D1 pin 6 D2 pin 3 D2 pin 7 D4 pin 4 D3 pin 8 D4 The Touch it XPC offers two Ethernet network interfaces 7 3 COM1 EIA 232 interface Picture 14 pin assignment EIA 232 interface DB9 male socket COM1 pin 1 DCD pin 6 DSR pin 2 RX pin 7 RTS pin 3 TX pin 8 CTS pin 4 DTR pin 9 RI pin 5 GND 7 4 VGA Picture 15 pin assignment monitor interface VGA pin 1 red pin 6 GND pin 11 ID0 pin 2 green pin 7 ...

Страница 16: ... time to time 8 2 Repairs DANGER Only the qualified staffs are allowed to carry out the repairs The incorrect repair may lead to serious danger for the user 8 3 Cleaning DANGER Disconnect the Touch Panel from the supply voltage before cleaning CAUTION Do not clean the touch sensitive surface of the monitor with detergents containing solvent or acid INFORMATION Use a humid and soft cloth with gentl...

Страница 17: ...ist Elektronik Touch surface damaged Send the Touch Panel for repair to Christ Elektronik GmbH Touch point displaced which means the pres sure point and the indi cation field are not one above the other Wrong calibration Calibrate the Touch Panel Clock does not work Battery empty Only the manufacturer Christ Elektronik GmbH is allowed to replace the internal lithium battery If any disturbance occu...

Страница 18: ... IIS Components Page File Support Enhanced Write Filter RAM API EWF Manager Console EWF NTLDR System Restore On Screen Keyboard German English Language Support Media Player 11 Interfaces USB 2 x USB2 0 Typ A LAN 10 100 1000 MBit Ethernet RJ45 x 2 Serial Port EIA 232 VGA monitor port DB15 Audio optional Line In Line Out Mic In Power Supply Supply Voltage nominal 24 V DC Voltage domain 12 36 V DC Po...

Страница 19: ...nt anodised aluminium Chassis wall cabinet galvanised metal Chassis VESA anodised aluminium Weight kg 1 4 2 5 4 6 User Environment Operating Temperature 0 to 50 C Storage Temperature 10 to 70 C Humidity 5 to 80 non condensing Degree of Protection Front IP 65 Degree of Protection Chassis IP 20 Certification CE ...

Страница 20: ...19 E461201 11 Scale Drawing 11 1 VESA Housing Picture 16 dimensions Touch it XPC 7 ...

Страница 21: ...E461201 20 T T T o o o u u u c c c h h h P P P a a a n n n e e e l l l Picture 17 dimensions Touch it XPC 10 4 ...

Страница 22: ...21 E461201 Picture 18 dimensions Touch it XPC 15 ...

Страница 23: ...E461201 22 T T T o o o u u u c c c h h h P P P a a a n n n e e e l l l 11 2 Switchgear Cabinet Housing Picture 19 dimensions Touch it XPC 10 4 with fan ...

Страница 24: ...23 E461201 Picture 20 dimensions Touch it XPC 10 4 fanless ...

Страница 25: ...E461201 24 T T T o o o u u u c c c h h h P P P a a a n n n e e e l l l Picture 21 dimensions Touch it XPC 15 with fan ...

Страница 26: ...25 E461201 Picture 22 dimensions Touch it XPC 15 fanless ...

Страница 27: ...E461201 26 T T T o o o u u u c c c h h h P P P a a a n n n e e e l l l 11 3 In Wall Housing Picture 23 dimensions Touch it XPC 10 4 ...

Страница 28: ...27 E461201 Picture 24 dimensions built in housing for Touch it XPC 10 4 ...

Страница 29: ...E461201 28 T T T o o o u u u c c c h h h P P P a a a n n n e e e l l l Picture 25 dimensions Touch it XPC 15 ...

Страница 30: ...29 E461201 Picture 26 dimensions built in housing for Touch it XPC 15 ...

Страница 31: ...E461201 30 T T T o o o u u u c c c h h h P P P a a a n n n e e e l l l 11 4 Open Frame with Front USB Picture 27 dimensions Touch it XPC 10 4 ...

Отзывы: