5.2
Display and operation
Display
128*64 Display with varying background lighting
Control elements
3 membrane buttons
5.3
Measuring principle and accuracy
Measuring principle
Voltage is measured directly at the load and current is measured by
a precision shunt.
Measuring rate
approx. 1 second
Sampling rate
approx. 2000 Hz
Open-circuit recognition
If I < 0,002 Ampere current and power values are set to zero.
It P < 0,2 Watt power values and current are set to zero.
In this case the power factor is set to 1,00.
The type of resistance is set to ohm-resistance.
EEPROM-Memory
All readings are saved even after unplugging
Measuring error
± 0,3 % ± 3 digit from reading at power factor > 0,3
5.4
Voltage supply
Connection
Socket at the adapter, permanent load max. 16 A
Supply voltage
100 - 264 V
AC
, 47 - 63 Hz
Power consumption
< 4 VA
5.5
Enviroment and dimensions
Dimensions
ABS plastic casing approx. 200*95*35 [mm] (L*W*H)
Weight
approx. 490 g
Connection cable
approx. 1,2 m
Working temperature
0
°
C - 50
°
C, dew not permissible
Degree of protection
IP 50 according to DIN EN 60529 (with USB-interface IP40)
with seal kit even higher values are permissible
Protection class
Protection class II (protective insulation) according to DIN EN
61140
Measuring category
CAT II